The type of cable (H07-VK, MX, etc.) should be defined by the installer according to the application type and applicable
standards.
For applications where the electricity network may be either 115VAC or 230VAC, always choose the cross section
recommended for 115VAC.
Always use cable markers without insulating collars in accordance with installation standards governing AC network
input connections.
The rating of the upstream circuit-breakers should match the equipment's requirements.
Mounting of AC supply connector
The AC input must be made using a WAGO connector type WINSTA reference770-103.
Remarks :
The YPOWER chargers work as soon as they are powered on. (Input cable connected and powered)
The YPOWER chargers stop as soon as they are not under voltage (disconnected from AC network or installation circuit
breaker in OFF position).