6. Preparation for installing the unit
When deciding the location of the unit and planning your installation, you must follow a set of guidelines based on
the specifications of the unit.
6.1. Environment
•
Place the charging stations in a place that is accessible for installation and maintenance work and which
permits them to be operated and the indicator LEDs to be read.
•
Do not place any material that is sensitive to high air temperatures near to the air outlets.
•
Avoid corrosive environments that may affect the proper operation of the unit.
•
Never place any object on top of the unit.
6.2. Environmental conditions
Environmental conditions must be taken into account when choosing the location of the unit.
It should be borne in mind that moderate condensation may occasionally occur as a consequence of temperature
variations. For this reason, apart from the unit's own protection, it is necessary to monitor these charging stations
once they have been started up on sites where the conditions described above are not expected to be present.
In the event of condensation, never apply voltage to the unit.
6.3. Supporting Surface and Fastening
To guarantee good heat evacuation and promote sealing, the charging stations must be placed on a perfectly
vertical wall or, failing this, with a slight slope of a maximum of +80° or -80°.
Reserve a solid wall to which to attach the unit. It must be possible to drill the wall and fit suitable wall anchors
and self-tapping screws to support the unit's weight.
6.4. Opening the housing
To open the housing from its main access, follow the figures below.
14
Environmental conditions
Minimum temperature
Minimum surrounding air temperature
Maximum surrounding air temperature
Maximum relative humidity without condensation
-20 ºC
-20 ºC
70 ºC
95%
ABA2023IQM01_ - 7.55.4.412.2 - Installation and Operation Manual