Preparation for installing the unit
6. Preparation for installing the unit
When deciding the location of the unit and planning your installation, you must follow a set of guidelines based on
the specifications of the unit.
6.1. Environment
•
Place the charging stations in a place that is accessible for installation and maintenance work and which
permits them to be operated and the indicator LEDs to be read.
•
Do not place any material that is sensitive to high air temperatures near to the air outlets.
•
Avoid corrosive environments that may affect the proper operation of the unit.
•
Never place any object on top of the unit.
6.2. Environmental conditions
Environmental conditions must be taken into account when choosing the location of the unit.
Maximum relative humidity without condensation
It should be borne in mind that moderate condensation may occasionally occur as a consequence of temperature
variations. For this reason, apart from the unit's own protection, it is necessary to monitor these charging stations
once they have been started up on sites where the conditions described above are not expected to be present.
In the event of condensation, never apply voltage to the unit.
6.3. Supporting Surface and Fastening
The units must be attached to an even and solid surface, and must be placed in a perfectly vertical position.
The surface on which to install the products must be suitably prepared and made according to the type of soil in
order to guarantee the correct stability of the product during its use.
For this purpose it is advisable to make a stand where drown the fixing tie-rods (not supplied) to be used to fix the
charging station. The tie rods must be positioned according to the dimensions in chapter 7.2.
Proceed with the fixing of the charging station on the appropriately prepared area, keeping the distances between
the station and the surrounding environment as shown in the figure.
ABA2022IQM01_ - 7.55.4.495.7
ABA2022IQM01_ - 7.55.4.413.0 - Installation and Operation Manual
Environmental conditions
Minimum temperature
Minimum surrounding air temperature
Maximum surrounding air temperature
-20 ºC
-20 ºC
70 ºC
95%
Gewiss
EN
ES
FR
IT
HU
13