Gewiss
8. Communication accessories
These charging stations have an RS-485 data bus, and the JOINON Parking stations have two RJ45 connectors
that allow a RS-485 connection between different stations.
All the charging stations can be accessed either locally or remotely. For remote connection they use an external
modem located in the installation or a modem supplied in the charging station if requested upon placing the order.
This section explains the wiring process for local connection, which is available as standard in JOINON Parking
stations.
In order to install and operate the communication accessories that enable remote communication,
see the Communication Accessory Manual for JOINON charging stations.
Los cable glands required for the communications cabling are not supplied with the charging station.
The required cable gland size is M16.
8.1. Local communication
8.1.1. JOINON Home
In JOINON Home communication is not included as standard and requires the installation of an optional accessory.
Follow the instructions below to complete the local connection:
1.
Connect the communication ring.
First station
The three positions of the middle communication card switches must be OFF. At the ends of the
communication ring, position 3 must be ON.
24
Intermediate station
ABA2023IQM01_ - 7.55.4.412.2 - Installation and Operation Manual
ABA2023IQM01_ - 7.55.4.494.0
Communication accessories
Final station