10 Troubleshooting
WARNING
Risk of burns
The welding torches reach very high temperatures during welding.
• Allow the welding torches to cool down.
• Wear the correct protective gloves.
NOTICE
• Maintenance and cleaning work must only be carried out by qualified personnel (in
Germany, see TRBS 1203).
• Always wear your personal protective equipment when performing maintenance and
cleaning work.
• Remove any adhering weld spatter.
• Ensure that all threaded fittings are tight.
9.1 Cable assembly
1 Check that all threaded fittings are tight and inspect wear parts for visible damage. Replace
if necessary.
9.2 Cutting torch
1 Check that all threaded fittings are tight and inspect wear parts for visible damage. Replace
if necessary.
2 The electrode must be replaced if the weld penetration is deeper than 1.5 mm.
3 Clean the cutting torch head regularly to remove cutting spatter.
4 Check the safety shut-off mechanism's contact pins to ensure that the spring function is
working properly. If required, clean the protective cap's contact ring to ensure a reliable
contact. Replace if necessary.
ABICOR BINZEL offers factory repair services.
10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorised persons
Improper repair work and modifications to the product may lead to serious injuries and
damage to the device. The product warranty will be rendered invalid if work is carried out on
the product by unauthorised persons.
• Operating, maintenance, cleaning and repair work must only be carried out by qualified
personnel (in Germany, see TRBS 1203).