IMPORTANT RULES
STORAGE TANKS WITH INDIRECT HEATING AND ONE HEAT EXCHANGER/ STORAGE
TANKS WITH INDIRECT HEATING AND TWO HEAT EXCHANGERS
Dear Clients,
The instruction manual and the technical description are prepared in order to
acquaint you with the product and the conditions of proper installation and
usage. Read them carefully and follow them.
The observance of the instructions contained herein is in the interest of the buyer
and represents one of the warranty conditions, outlined in the warranty card. The
non-observance of the instruction can be reason of losing warranty!
• This manual is an integral part of the appliance. It must be kept with care and
must follow the appliance if the latter is transferred to another owner or user and/
or to another installation.
• Read the instruction and tips very carefully. They will help you secure a safe
installation, use and maintenance of your appliance.
The insta llation is at the buyer's expense and must be carried out by a
professional technical person from the sector in accordance with instructions in
the manual.
Attention! Improper installation and connection of the appliance may make
it hazardous for the health and life of consumers. It may cause grievous and
permanent consequences, including but not limited to physical injuries and/or
death. Improper installation and connection of the appliance may also lead to
damage to the consumers' property /damage and/ or destruction/, or to that of third
persons, as a result of, but not limited to flooding, explosion and/or fire.
Installation, connection to the main water and power supply, and putting into
operation must be carried out by certified electricians and technical personnel
certified in installation of this category of appliances, who have obtained their
license in the state where the installation and commissioning of the appliance are
carried out, and in compliance with its local legislation.
IMPORTANT! Non observance of below described rules leads to warranty fault
and the produser bear no more responsibilities for you appliance!
The use of the appliance for any purpose other than that it is intended is
prohibited. (p.ІII)
Do not use the storage tank if it is not filled with water.
The installation and maintenance must be carried out by a professional from
the sector in accordance with manufacturer's instructions. (p.V 1,2,3, 4).
The appliance must only be installed in premises with normal fire resistance.
There should be a siphon connected to a plumbing drainage. The premises
should be protected from freezing and the temperature should never be lower
than 4°C.
When connecting copper pipes to the inlets and outlets, use an intermediate
dielectric connection. Otherwise there is a risk of contact corrosion that can occurs
on the connection fittings!
The safety valve(5) must be mounted on the cold water supply pipe, the
incoming water's direction fig.(5 и 6) Additional stopcocks must not be mounted
between the safety return-valve and the water heater.
Exception: If the local regulations (norms) require the usage of another protection
valve or mechanism (in accordance with EN 1487 or EN 1489), it must be bought
additionally. For mechanisms operating in accordance with EN 1487 the announced
operational pressure must be no more than 0.7 MPa. For other protection valves,
the pressure at which they are calibrated must be 0.1 MPa lower than the one
marked on the appliance's sign.
During use (water heating mode), the dripping of water from the safety return-
valve's drainage opening is normal. The same must be left open to the atmosphere.
The safety valve and the pipe between the valve and the water heater must be
protected from freezing. During hose draining - its free end must be always open
to the atmosphere (not to be immersed). Make sure that the hose is also protected
from freezing.
In order to secure the water heater's safe operation, the safety return-valve
must undergo regular cleaning and inspections for normal functioning /the valve
must not be obstructed/, and for the regions with highly calcareous water it must
be cleaned from the accumulated lime scale. This service is not provided under
warranty maintenance.
If the probability exists for the premise's temperature to fall below 0°C, the
storage tank must be drained via raising the safety return-valve's lever. If upon
turning the valve's knob when the water tank is full, water do not start running from
the valve's drainage opening, this is a signal of malfunction and the appliance's use
must be discontinued.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
It is necessary to maintenance the water heater regarding the described rules,
to change duly the anode protector and to clean the limestone also after the
warranty period. It is necessary to keep the rules for preventive maintenance,
replacement of magnesium anode protector and cleaning even after guarantee
period. (p.VI;VII;VIII)
This device is intendet for heating of potable water in liquid state. using different
fluids in different states leads to warranty violation!
Device's heat exchangers are intended for use with circulating clean water and
mixture of it and Propylene GLYCOL at liquid state.
The presence of anticorrosion additives is obligatory. Using different fluids in
different states leads to warranty violation!
English
IMPORTANT! Usage of this device at temperature and pressure level above
prescribed leads to warranty violation!
II.
TECHNICAL DATA
1. Storage Volume of tank, L - see the appliance's rating plate
2. Net Weight - see the appliance's rating plate
3. Heat exchanger surface- see the appliance's rating plate
4. Solid insulation PU
Storage Volume of tank, Ltr
200 ÷ 500
800 ÷ 2000
5. Volume of heat exchanger - see the appliance's rating plate
6. Standing heat loss- see the appliance's rating plate, see Annex II
7. Max.temperature of the tank - see the appliance's rating plate
8. Max.temperature of heat exchangers - see the appliance's rating plate
9. Max. design pressure of water side - see the appliance's rating plate
10. Max. design pressure of heating side - see the appliance's rating plate
11.Heat exchanger performance| - see the appliance's rating plate
12. Max.amount of water - see the appliance's rating plate
13.Name and address of the manufacturer - see the appliance's rating plate
III.
INTENDED USE
The appliance is intended to supply domestic hot (potable) water to households equipped
with a piping system working at pressure below 6 bar (0,6 MPa).
The content of chlorides in the water should be below 250 mg / l, and its electrical
conductivity to be in the range of 100 μS/cm to 2000 μS/cm. The heat exchangers
must be installed to the closed heating systems with pressures up to see the
appliance's rating plate. Heat carier must be circulating water or a mixture thereof
with propylene glycol and anticorrosion additives!
IV.
DESCRIPTION OF THE APPLIANCE
Depending on the storage tank model, it can has one or two built-in heat
exchangers (serpentines)(see Annex I). The connections to the appliance should be
made following the marked outlets and inlets, described below: T - for temperature
indicator (the indicator is included in the kit of the appliance). TS1, TS2, TS3 -
for mounting temperature sensors (each heat exchanger can be controlled by
temperature). If the storage tank is equipped with one heat exchanger there will
be only one outlet "TS1" available. An electric heater can be fitted to the product
for which a pipe outlet marked EE (HE) is provided . Follow the technical data for
choosing the proper power of the heating element.
FLANGE /near the bottom/ for servicing and cleaning - it can be used for mounting
an electrical heating element too. R - for hot water recirculation systems.
A description of the pipe outlet s and technical characteristics are given in Table
1/2/4/6/7/8.
ATTENTION: The electrical heating element should be approved from the
producer of the high capacity water heater. Otherwise the producer does
not follow any warranty conditions and it is not responsible for any abnormal
work of the appliance.
V.
MOUNTING AND CONNECTION
ATTENTION! Qualified technicians must perform all technical and electrical
assembly works.
1.
INSTALLATION
Storage tanks are delivered on an individual transport pallet. If the high capacity
water heaters are used in premises with low humidity and flat floor you can leave
the pallet as it is mount on the appliance, otherwise – please follow the described
steps bellow (Fig. 5):
Put the appliance in horizontal position;
Unscrew the three bolts which hold the pallet to the water heater;
Mount the adjustable feet directly to the appliance;*
Put the storage tank in vertical position and adjust the level using the feet.
* If the adjustment feet are delivered in separate parts you can assemble them as
follow (Fig. 6):
put the part 1 on bolt 2 which is unscrewed from the pallet
put the washer 3 which is removed from the pallet
Screw on the nuts 4 which are delivered with the appliances
ATTENTION! In order to prevent injury to user and/or third persons in the
event of faults in the system for providing hot water, the appliance must be
mounted in premises outfitted with floor hydro insulation (or) plumbing drainage.
2.
MOUNTING OF "SOFT" PU INSULATION (800-2000L)
For the installation of insulating material two persons, in the case of very big boiler,
three persons are needed. The temperature of the room where the fitting takes place
should be at least 18°C. The insulation set should be stored at above mentioned
temperature at least one hour before operating!
In the next step both sides of the zipper have to be pulled with light traction into
the direction of the arrows shown in FIG.11. Please take care that the prefabricated
holes stay in place and the connections are accessible all the time.
EN
Solid Insulation PU, mm
50
100
7
Instructions for use and maintenance