OUTPUT ELECTRICAL CHARACTERISTICS
Rated voltage
(V)
Rated frequency
(Hz)
Maximum current
(A)
Overload capacity
Outlets
Efficiency
BATTERIES AND BATTERY CHARGER CHARACTERISTICS
Number of
batteries
String
(V)
Capacity
(Ah)
Battery type
Back-up time at
50% load
(min)
Charge current
(A)
Charging time
Battery cut-off
(V)
Battery
replacement
Battery extension
3 110 65
3 112 60
Keor SPE R/T 750
3.41
3 110 65
3 112 60
Keor SPE R/T 750
valve-regulated lead-acid, maintenance free
6 hours to 90% (after discharge with 50% fully resistive load)
3 110 66
3 112 61
Keor SPE R/T 1000
230 ; ~ 1ph
Battery mode: ±5%
50 / 60 ± 1% (battery mode)
4.55
Normal mode
<106% : continuous
<120% : 5min
<150% : 1min
>=150% : 10sec
Battery mode
<105% : continuous
<120% : 10sec
>=120% : immediate shut-down
5 x IEC C13
up to 98%
3 110 66
3 112 61
Keor SPE R/T 1000
4
1x24
7
3 cells VRLA
> 10min
1.2 max
1.6 V/cell at medium/full load
1.83V/cell at light load
Hot-swappable
no
KEOR SPE R/T
Installation and User Manual
3 110 68
3 112 63
Keor SPE R/T 1500
3 110 68
3 112 63
Keor SPE R/T 1500
6.82
6
1x36
71