Télécharger Imprimer la page

SICK GSE6S Mode D'emploi page 82

Publicité

ISTRUZIONI PER L'USO
it
5.3
Indicazioni sull'omologazione UL
82
I S T R U Z I O N I P E R L ' U S O | GSE6S
-xxAx1x70
-xxAx1x7E
-xxAx1xA0
-xxAx1xAE
D.ON, PNP: Q (≤ 100 mA)
-xxEx2x70
-xxEx2x7E
-xxEx2xA0
-xxEx2xAE
L.ON, NPN Open Collector Q (≤
100 mA)
-xxEx1x70
-xxEx1x7E
-xxEx1xA0
-xxEx1xAE
D.ON, NPN Open Collector Q (≤
100 mA)
Tabella 8: Entrata di test
GSO6Sx/xx2xxxxxx
GSO6Sx/xx3xxxxxx
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a)
max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b)
100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
+ (L+)
Q
‒ (M)
+ (L+)
+ (L+)
Q
Q
‒ (M)
‒ (M)
+ (L+)
Q
‒ (M)
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
9397275/2024-11-05 | SICK
Contenuti soggetti a modifiche senza preavviso
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
+ (L+)
+ (L+)
Q
Q
‒ (M)
‒ (M)
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)

Publicité

loading