Télécharger Imprimer la page

SICK GSE6S Mode D'emploi page 25

Publicité

5
Electrical installation
5.1
Notes on electrical installation
9397275/2024-11-05 | SICK
Subject to change without notice
NOTE
When mounting multiple through-beam photoelectric sensors next to each other, swap
the arrangement of the sender (GSO6S) and receiver (GEO6S) for every second pair.
Also maintain a sufficiently large distance between the pairs based on the light spot
diameter of the sender (GSO6S). See
Sender (GSO)
Receiver (GEO)
Sender (GSO)
Figure 2: Arrangement of multiple through-beam photoelectric sensors
Note the sensor's maximum permissible tightening torque of 0.4 Nm.
NOTICE
Equipment damage due to incorrect supply voltage!
An incorrect supply voltage may result in damage to the equipment.
Only operate the device with safety/protective extra-low voltage (SELV/PELV).
The sensor is a device of protection class III.
Only operate the device with an LPS (limited power source) in accordance with
IEC 62368-1 or an NEC Class 2 power supply unit.
NOTICE
Equipment damage or unpredictable operation due to working with live parts!
Working with live parts may result in unpredictable operation.
Only carry out wiring work when the power is off.
Only connect and disconnect electrical connections when the power is off.
The electrical installation must only be performed by electrically qualified person‐
nel.
Standard safety requirements must be observed when working on electrical
systems!
Only switch on the supply voltage for the device when the connection tasks have
been completed and the wiring has been thoroughly checked.
When using extension cables with open ends, ensure that bare wire ends do not
come into contact with each other (risk of short-circuit when supply voltage is
switched on!). Wires must be properly insulated from each other.
Wire cross-sections in the supply cable from the user's power system must be
selected in accordance with the applicable standards.
OPERATING INSTRUCTIONS
figure 2
and
section
10.3.
O P E R A T I N G I N S T R U C T I O N S | GSE6S
Receiver (GEO)
Sender (GSO)
Receiver (GEO)
en
25

Publicité

loading