OPERATING INSTRUCTIONS
en
6.3
Setting
6.4
Additional functions
30
O P E R A T I N G I N S T R U C T I O N S | GSE6S
Operating reserve
1,000
100
10
1
0
5
10
(16.40)
(32.81)
0
0
5
10
(16.40)
(32.81)
(49.21)
Distance in m (feet)
D
C
A
A)
Sensing range min. in m
B)
Sensing range max. in m
C)
Maximum distance range from receiver to sender
D)
Distance between sender / receiver recommended
Sensitivity adjustment
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
Operating reserve increased; counterclockwise rotation: Operating reserve reduced. It is
recommended to set the potentiometer to "Maximum".
The sensor is adjusted and ready for operation.
Sensors without adjustment possibilities
Sensor which it is not possible to set: the sensor is adjusted and ready for operation.
Test input
Test input: The GSE6Sx-xx2/GSE6Sx-xx3 sensors feature a test input ("TI" or "Test"
on the connection diagram
sender off and therefore check that the sensor is functioning correctly: If female cable
connectors with LED indicators are used, you must ensure that the TI is assigned
accordingly.
There must be no object between the sender and receiver; activate the test input (see
the connection diagram
[see table 4, page
Sender LED is switched off. The detection of an object is simulated. Use the following
table to check the function. If the digital output fails to behave in accordance with
table 8, page
28, check the application conditions. See section Fault diagnosis.
Operating reserve
1,000
100
10
1
15
20
0
(49.21)
(65.62)
Distance in m (feet)
17
20
0
15
20
0
(65.62)
B
A
[see table 4, page
26]), which can be used to switch the
26], TI at 0 V).
5
10
15
20
(16.40)
(32.81)
(49.21)
(65.62)
Distance in m (feet)
16
20
5
10
15
20
(16.40)
(32.81)
(49.21)
(65.62)
Distance in m (feet)
D
C
B
see
9397275/2024-11-05 | SICK
Subject to change without notice