en - Installation notes
Installation requirements
 Risk of injury or damage to property due to improper installation.
Incorrect installation of the tumble dryer can lead to personal injury or damage to prop-
erty.
It is recommended that installation and commissioning be accomplished by Miele Ser-
vice or an authorized dealer.
In the State of Massachusetts a licensed Plumber or Pipe fitter must be used.
The tumble dryer must be installed in accordance with all relevant regulations and stan-
dards. Observe all local codes.
The dryer must only be operated in a room that has sufficient ventilation and which is
frost-free.
The tumble dryer must not be installed behind a closeable door or a sliding door. The
maximum opening angle of the tumble dryer door must not be limited by objects or doors.
It must be possible to fully open the tumble dryer door at any time.
The dryer, when installed, must be electrically grounded in accordance with local codes
or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.1.
The dryer must not be installed or stored in an area where it will be exposed to water
and/or weather.
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper operation.
Electrical connection
 Danger caused by improper electrical connection.
There is a risk of serious damage, injury, or even death if installation work is carried out in-
correctly.
All electrical connection work must be carried out by a qualified electrician in accordance
with local and national safety regulations.
The electrical installation must be carried out in accordance with IEC 60364-4-41 or the
local regulations.
The required supply voltage, power rating, and fuse rating can be found on the data plate
on the tumble dryer. Ensure that the supply voltage matches the voltage quoted on the
data plate before connecting the machine to the electricity supply.
Connection to a supply voltage other than the one quoted on the data plate can damage
the tumble dryer if the voltage is too high.
If more than one voltage is specified on the data plate, the tumble dryer can be converted
for connection to the relevant input voltage. This conversion must be performed by
Miele Service or by an authorized dealer only. During the conversion, the wiring instructions
given on the wiring diagram must be followed.
The tumble dryer can either be hard-wired or connected using a plug-and-socket connec-
tion in accordance with IEC 60309-1. For a hard-wired connection, an all-pole disconnect
switch must be available at the installation site.
A disconnect switch is a switch which ensures a contact opening of more than 1/8"
(3 mm). These include circuit breakers, breakers, and contactors (IEC/EN 60947).
If the power supply cannot be permanently disconnected, the disconnect switch (including
plug and socket) must be safeguarded against being switched on either unintentionally or
without authorization.