Table I
Components
Exhaust air hose (flexible aluminum)* / pipe (temperature resistance
min. 175°F (80°C))
– 3' 3" (1 m) laid straight or 3' 3" (1 m) straight pipe
– 45° bend (radius of bend = 10"(0.25 m))
– 90° bend (radius of bend = 10" (0.25 m))
The use of a wall pipe or window connection is regarded as an exception to the design principles of the
exhaust air management system. This must be carried out in accordance with the applicable local
building regulations. Seek approval from the relevant building inspector where necessary.
Wall pipe* or window connection*
– with inserted grate
– with non-return flap (swinging flap)
Berechnungsbeispiel
Non-return flap*
* optional accessories
,
Ausnahmen bei der Auslegung
Table II
der Abluftführung sind gemäß Bau-
Maximum permissible total ducting length
ordnung der Länder auszuführen.
65' (20 m)
Fragen Sie den Bezirksschornstein-
130' (40 m)
fegermeister/die Bezirksschornstein-
262' (80 m)
fegermeisterin.
Sample calculation
A
Mauerrohr, mit Gittereinsatz
= 1 x 3,8 m Vergleichsrohrlänge = 3,8 m
B/D 2 Bögen, 90°
= 2 x 0,8 m Vergleichsrohrlänge = 1,6 m
C
0,5 m Rohr
= 0,5 x 1 m Vergleichsrohrlänge = 0,5 m
Gesamtrohrlänge
Resultat: Die Gesamtrohrlänge beträgt
weniger als 20 m (laut Tabelle II). Des-
Zuluftführung und Abluftführung
Bemaßung Abluftanschluss
Draufsicht
Required diameter
4" (100 mm)
5" (125 mm)
6" (150 mm)
Rückansicht
= 5,9 m
en - Installation notes
Relative pipe length
3' 3" (1.0 m)
2' (0.6 m)
2' 7 1/2" (0.8 m)
12' 5 5/8" (3.8 m)
4' 11" (1.5 m)
46' 11" (14.3 m)