Set-up and operation
Set the power switches to off (O) and the thermostat dial to 5 (maximum).
Insert the plug into a suitable and properly functioning earthed socket.
In order to switch on the heater, set one or both power switches to l.c.q. II. The light(s)
on the related switch(es) turn(s) on and the heater starts to function. For slow heating,
a small rise in temperature or a small space, choose setting I (800W). For quick
heating, a bigger temperature rise or a larger space, choose setting II (1200W). I and II
together give full power (2000W).
Once the space has reached the right temperature, turn the thermostat dial to 0 until
you hear a click. If you leave the dial in this position, the heater will maintain the
current temperature by regularly switching on and off. When the heater is switched
on, the light(s) will go on. By turning the thermostat dial to the left/right, you
increase/decrease the set temperature.
If so desired, you can now switch to a lower power level.
To switch off, turn the power switches to off (O). The heater switches off. Unplug.
Note! It takes a long time for an oil filled radiator to cool down. Give the radiator
sufficient time to cool down before touching or moving (use handle!).
Safety features
Tipping safeguard
The heater is fitted with a tipping safeguard which automatically shuts off the appliance if
it inadvertently falls over. When the heater is returned to its upright position, it will
resume functioning as normal but, before reusing, switch off, unplug and check for
damage. Do not use the heater if it is damaged or malfunctioning, but have it
inspected/repaired!
Overheating safeguard
In case of internal overheating, the overheating safeguard will switch the heater off. This
may occur if the heater cannot give off enough heat or if it or cannot draw in enough fresh
air. As mentioned above, this is generally caused by (partially) covering the heater,
obstructing the air intake and/or outlet grills or installing the heater too close to a wall or
something similar. When the overheating safeguard has switched the heater off, you need
to set the power switches to 'O' (off) and unplug the heater. Give the heater time to cool
down, remove the source of the overheating and use as normal. If the problem persists or
if you have not been able to trace the source of the overheating, turn the heater off
immediately and unplug. Contact a service point to have the heater repaired.
Cleaning and maintenance
Keep the heater clean. Deposits of dust and dirt in the appliance are a common cause of
overheating so these should be removed regularly. Switch off the heater, remove the plug
from the socket and allow the heater to cool down before cleaning or carrying out
maintenance work.