Télécharger Imprimer la page

CARE FITNESS MEDLINE MED-730 Manuel D'utilisation page 16

Publicité

FAULT CODE
FAULT DESCRIPTION
Communication abnormal:
The control and computer
E1
communication after start
E2
Explosion-Proof Protection
No Speed Wireless Sensor
E3
Network
E4
Incline self-learning fault
E5
Over-Current Protection
Controller self-checking
E6
E7
EEPROM is broken
To order spare parts
To guarantee an efficient service, make sure you have the following items before you contact our After Sales
Service:
The name or reference of the product.
The manufacturing number shown on the main chassis and on the packing box.
The number of the missing or faulty part shown on the exploded view of the product described in this manual.
Stop and go into fault. The machine can't running, the computer shows
fault code "E01", and the buzzle will ringing three tone.
Possible reasons:Communication obstructed between controller and
has abnormal
computer, please check the wire and make sure the wire connect well
and the wire without and danger.
Stop and go into fault. The machine shows fault code "E06". Other
areas show blank, and can not restart.
Possible Reason: Check the motor wire if connect well, and then
connect it again.
Possible Reasons:Can't receive the motor speed sensor feedback
above 3 seconds, please check sensor plug and motor connect wire
and the controller.
Check incline motor sense wire and AC wire are inserted well; AC wire
is right inserted according to the indentify in the incline motor; make
sure the incline motor wire without damager; after check those, press
the button on controller, then start self-learning again.
Stop and go into fault status, computer shows fault code "E03".Other
areas show blank. After 10 seconds will go into ready mode, and can
restart.
Possible Reasons:Over the rated load cause too much electricity that
make system Self-preservation or some parts blocked and make DC
motor can't process. Adjust the machine and restart. Another please
check the DC motor or controller have any burned smell or not. If yes,
please change the motor or controller. Another make sure the power
and voltage is comply with standard.
Change the controller.
error
Change the controller.
After Sales Service
Email: service-uk@carefitness.com
FAULT PROCESSING

Publicité

loading