Télécharger Imprimer la page

NewAir NCI080SS00 Manuel De L'utilisateur page 30

Publicité

1.
Unplug the power cord and turn off the ice maker. Keep the unit
connected to the water supply and drainpipe, then shut off the main water
supply switch.
2.
Open the door and scoop out all the ice cubes. Either discard them or save
them in an ice chest or cooler.
3.
Making the cleaning solution. Mix the Nu-Calgon Nickle Safe Ice Machine
Cleaner with water to make the cleaning solution.
WARNING: Wear rubber gloves and safety goggles(and/or face shield)when
handing Ice Machine Cleaner or sanitizer.
Use a plastic or stainless-steel container with more than 4-liter capacity, mix
300 ml of Nu-Calgon Nickle Safe Ice Machine Cleaner with 2.8 liters warm
water (120℉-140℉). Then, divide the mixture into 2 equal shares in 2 cups.
4.
Check to be sure that the drainpipe of the water tank has been installed
properly in the slot of the tank wall. Then, pour one cup of Nickel-Safe Ice
Maker Cleaning Solution into the water tank. Wait for approximately 5
minutes.
5.
Turn on the power to the ice maker, then press and hold the "TIMER
CLEAN" button on the control panel for at least 5 seconds to enter the self-
cleaning program. As described above, the water pump runs for 8 minutes
and stops for 3 minutes, then repeats this cycle. The total duration time is
20 minutes for one self-cleaning program.
During this process, the "CLEAN" light will always be on, and the digit window
will indicate the remaining time.
6.
After the self-cleaning program is complete, remove the drainpipe from
the water tank and drain the cleaning solution down to the lower ice
storage bin. Shake the unit slightly to drain the cleaning solution
completely. Then, reinstall the drainpipe to the slot in the water tank.
7.
Repeat steps 4-6 to clean the ice making assembly system as often as is
necessary.
WARNING:
• The ice machine cleaner contains acids.
• DO NOT use or mix with any other solvent-based cleaning products.
www.newair.com
EN
30

Publicité

loading