To ensure proper ventilation for your ice maker, the front of the unit must be
completely unobstructed (at least 10 inches of free space). Allow about 2
inches clearance at rear, and 2 inches at the top for proper air circulation. The
installation and placement should allow the ice maker to be pulled forward for
servicing if necessary.
When installing the ice maker under a counter, follow the recommended
spacing dimensions shown above. Place electrical and water supplies and drain
fixtures in the recommended locations as shown.
Choose a well-ventilated area with temperatures above 50℉ and below 90℉.
This unit must be installed in an area protected from the elements, such as
wind, rain, water spray, or drips. The ice maker requires a continuous water
supply with 1-8 bar pressure as required in the above specification table. The
temperature of the water supplying the ice maker should be between 41℉ and
77℉ for proper operation.