(9) WARRANTY
The Kinetec® guarantee is strictly limited to the free replacement
or factory repair of the part or parts that are recognized to be
defective.
KINETEC SAS guarantees Dr Aktive® Cryo Pro for 2 years against
any manufacturing defect, from the date of purchase by the
consumer.
KINETEC SAS is solely accredited to judge the application of the
guarantee for its devices.
The guarantee cannot be applied if the device has been used
abnormally or was used in conditions of use other than those
contained in our user manual.
The guarantee shall also not apply in the event of deterioration
or accident
resulting from negligence, compliance
maintenance fault resulting from a transformation of the
equipment or an attempt to repair equipment.
(10) DISPOSAL AND RECYCLING
• Packaging: The packaging must be separated from plastic and
paper/cardboard components and placed in specific recycling
locations.
• Cooler: It contains electronic components, cables, plastic, steel
and aluminium parts. When the device is no longer functional,
dismantle and separate into groups of materials and place
them in approved recycling units or return the device to
KINETEC SAS for destruction. Or contact local authorities to
establish the appropriate method of disposing of parts and
accessories that are potentially dangerous to the environment.
• Cuff and hose: Put it in specific recycling locations.
(11) TROUBLESHOOTING
1. Please make sure that AC adaptor is
correctly inserted into the electrical
outlet.
Cooler will not
2. Please make sure that the power plug is
turn on
correctly inserted into the cooler.
3. If you operate with battery, please
make sure that the power bank is fully
charged.
1. Please make sure whether it is
There is water
condensed water.
on the surface of
2. If the cuff leaks, stop using it
the compress
immediately and contact the distributor
pad
for repair.
1. Running for 2-3 minutes, the noise will
Loud noise when
be reduced.
cold treatment
2. If the noise is always very loud, please
starts
stop using it and contact the distributor
for maintenance.
Weight of the cooler: ............................................ 1.99kg (empty)
Capacity: ................................................................ maximum 3.6L
Acoustic pressure: ............................................................ < 50dBA
Pressure level: ............................................ 60mmHg – 120mmHg
Power supply voltage: ............. Input: .......100-240V
Electric type and class: ....................................... BF Type / Class II
Storage/transport conditions:
Ambient temperature: ............. -25°C to +70°C / -13 to 158°F
Relative humidity: .. from 20% to 90% without condensation
Atmospheric pressure: ................... from 700hPa to 1060hPa
Operating conditions:
or
Ambient temperature: .............. +5°C to +40°C / -13 to 158°F
Relative humidity: .. from 15% to 90% without condensation
Atmospheric pressure: ................... from 700hPa to 1060hPa
Follow the
instructions for use
CE marking of
conformity
Keep away from sunlight
and heat source
Keep dry
Class II device
(double insulation)
BF TYPE device
(protection from electric
shocks)
Alternating current
Unique Device
Identifier information
Contains electric and electronic components; do not
dispose of with household waste.
EN
(12) SPECIFICATIONS
Output: ...................... 12V
(13) SYMBOLS USED
Manufacturer
Medical device
Device reference
Device serial number
Manufacture batch
number
Manufacture date
Direct current
Unique Device
Identifier carrier
50/60Hz
2A