GB
MT
nection cable, which is available from
the customer service organisation.
• Only use grinding discs where the in-
dicated rotational speed is at least as
highaswhathasbeenspecifiedonthe
name plate of the device.
• Carry out a visual inspection of the
grinding disc before use. Do not use
any damaged or deformed grinding
discs. Replace any damaged or worn
grinding discs.
• Make sure that the sparks produced by
grinding do not present a danger, e.g.
reachpeopleorigniteflammablesubs-
tances.
• Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding, brushing and
cutting.
• Neverkeepthefingersbetweenthe
grinding disc and spark protection or in
close proximity to the protective hoods.
Thereisariskofcrushing.
• Therotatingpartsofthedevicecannot
be covered due to functional reasons.
Therefore,proceedcautiouslyandhold
theworkpiecefirmlyinordertoavoid
slipping which could cause your hands to
come into contact with the grinding disc.
• Theworkpiecegetshotduringgrinding.
Do not touch the machined area, allow
ittocooldown.Thereisariskofbur-
ning. Do not use coolants or the like.
• If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
• Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
34
RESIDUAL RISKS
Even if properly operating and handling this
electric tool, some residual risks will remain.
Due to its construction and build, this electric
tool may present the following hazards:
a) Lung damage if suitable respiratory
protection is not worn.
b) Hearing damage if suitable ear protec-
tion is not worn.
c) Damage to health due to
- touching the area of the grinding tool
which is not covered;
- ejection of parts of workpieces or
damaged grinding discs.
d) Health injuries which result from swin-
ging hand and arm, in the event that
the device is used over a longer period
of time or is not used and maintained
properly.
Warning! During operation, this
electric tool generates an electro-
magneticfieldwhich,undercertain
circumstances, may impair the
functionality of active or passive
medicalimplants.Toreducetherisk
of serious or lethal injuries, we re-
commend that persons with medical
implants consult their doctor and the
manufacturer of their medical im-
plant before operating the machine.
Practical tips
When selecting the tool,
ensure that its specified per-
missible rotation speed is at
least as high as the maxi-
mum rotation speed speci-
fied on the angle grinder.
When selecting the disc, pay
attention to the maximum per-
missible diameter and the ma-