Napoleon BGD36CFPTRE Instructions D'installation Et D'opération page 31

Publicité

6.2
MINIMUM FRAMING DIMENSIONS
FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO
PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (35.6cm) WIDE AREA CENTRED
ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.
49"
1.25m
(TOP EXIT)
40 1/2"
1.03m
(REAR EXIT)
Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2"
(50.8mm) away from the side of the appliance. Thereafter, the depth of any protrusions must be equal to or
less than the distance from the side of the appliance up to a depth of 6" (152.4mm), after which no greater
clearance than 6" (152.4mm) is required. This can be considered a side wall with no length boundary.
WARNING
!
1 1/2"
38mm
MAX
14"
35.6cm
MIN
STEEL HEADER
REQUIRED (SUPPLIED)
1 1/2"
38mm
MAX
17 1/4"
43.8cm
40 3/4"
0.98m
40 1/2"
1.03m
31
EN
W415-1345 / C / 02.14.17