OCD5/MCD5-1999 / OWD5/MWD5-1999
TECHNICAL SPECIFICATIONS
Purpose of control
Method of mounting.
Supply voltage
Max. pre-fuse
Built-in interupter
Enclosure rating
Wire size, terminals
ELV limits realized
Output relay
Output, load
Control principle
Standby consumption
Battery backup
Battery life, typical
RF frequency band*
WIFI*
Security*
Dimensions
Build-in depth
Weight
Display
Control pollution degree
Overvoltage category
Type of action
Software class
Rated impulse voltage
Ball pressure temperature (TB)
EU registered design
Note: At very low ambient temperatues the display may respond slowly.
* Only valid for WiFi Touch Thermostats
Electrical underfloor heating
Wall mounting in a socket or
mounting box
100-240 VAC ±10% 50/60 Hz
16 A
2-pole, 16 A
IP 21
Current ≤ 13 A - 1.5 mm
wire
Current > 13 A to 16 A - 2.5 mm
solid core wire
SELV 24 VDC
Make contact - SPST - NO
Max. 16 A / 3600 W
PWM/PI
≤0.5 W
5 years (storage)
5 years (storage) 10 years (powered)
2.4 GHz
IEEE 802.11 b/g/n - 2.4GHz
WPA/WPA2
OxD5: H/82, W/82, D/40 mm
MxD5: H/84, W/84, D/40 mm
MxD5-UA: H/115, W/84, D/40 mm
22mm
≤200 g
176x220 pixels TFT - resistive touch
2
III
1.B
A
4kV
125°C
DM/082270
© 2021 OJ Electronics A/S
English
, solid core
2
,
2
13