Télécharger Imprimer la page

OJ Electronics OCD5 Manuel D'instructions page 11

Publicité

OCD5/MCD5-1999 / OWD5/MWD5-1999
Error codes
E0: Internal fault. The thermostat must be replaced.
E1: Built-in sensor defective or short-circuited. Replace the
thermostat, or use the floor sensor only.
E2: External sensor disconnected, defective or short-circuited.
Reconnect the sensor if disconnected, or replace the sensor.
E5: Internal overheating. Inspect the installation.
MAINTENANCE
The thermostat is maintenance free.
Keep the thermostat's air vents clean and unobstructed at all
times.
The thermostat may only be cleaned with a dry cloth.
APPROVALS AND STANDARDS
Regulations
OJ Electronics A/S hereby declares that the product is in
conformity with the following directives of the European
Parliament:
LVD - Low Voltage Directive
EMC - Electromagnetic Compatibility
RoHS - Restriction of the use of certain Hazardous Substances
RED - Radio Equipment Directive
Applied standards and approvals
According to the following standard:
EN 60730-1, EN 60730-2-9, EN 300 328, EN 301 489-17,
EN 301 489-1, EN 62479, EN 50559
Classification
Protection from electric shock must be assured by appropriate
installation. Must be installed according to the requirements of
Class II (reinforced insulation).
© 2021 OJ Electronics A/S
English
11

Publicité

loading

Ce manuel est également adapté pour:

Owd5Mcd5-1999Mwd5-1999