Operating Instructions
Transducer for AC current SINEAX I 542
Safety precautions to be strictly observed are marked
with following symbols in the Operating Instructions:
Contents
1. Read fi rst and then ... ................................................ 6
2. Brief description .......................................................... 6
3. Technical data ............................................................. 6
4. Mounting ..................................................................... 6
5. Electrical connections ................................................. 7
6. Commissioning and maintenance ............................... 7
7. Releasing the transducer............................................. 7
8. Instruments admissions .............................................. 7
9. Dimensional drawing ................................................... 8
10. Declaration of conformity ............................................ 8
1. Read fi rst and then ...
The proper and safe operation of the device
assumes that the Operating Instructions is
read carefully and the safety warnings given
in the various Sections

4. Mounting

5. Electrical connections
are observed.
The device should only be handled by appropriately
trained personnel who are familiar with it and authorised
to work in electrical installations.
Unauthorized repair or alteration of the unit invalidates
the warranty!

2. Brief description

The transducer SINEAX I 542 is designed to convert a
sinusoidal AC current into a DC current or voltage signal
proportional to the measured value. It does not require a
separate power supply.

3. Technical data

Measuring input
Nominal frequency:
50/60 Hz
Nominal input current: Please note the max. input current
on the type label!
Acc. to type with 2 measuring ranges
0 - 1/5 or 0 - 1.2/6 A, resp. 0-0.5 to
0 - 7.5 A (one measuring range
only)
Own consumption
at nominal
frequency 50 Hz:
2.5 VA with 20 mA output
2
1.7 VA with 5 mA output
1.5 VA with 1 mA output
6
VA with 10 mA output
Setting
(special feature):
Admissible alteration of full scale out-
put, variable sensitivity, adjustable
with potentiometer (see fi g. 4)
Setting range approx. 0.9 - 1.1 · I
(approx. ± 10%)
100%
Measuring output
DC current:
0-1, 0-5, 0-10 or 0-20 mA
Burden voltage:
15 V
External resistance:
See Section "5. Electrical connec-
tions"
DC voltage output
not superimposed:
0 - 1 to 0 - 10 V
External resistance:
See Section "5. Electrical connec-
tions"
Time response:
≤ 300 ms
Accuracy (acc. to IEC 688)
Reference value:
Input end value
Basic accuracy:
Class 0.5
Input:
0 - 100%
Temperature infl uence
(- 10 to + 55 °C):
0.2% / 10 K
Safety
Pollution degree:
2
Installation category:
III
Environmental conditions
Operating temperature: - 10 to + 55 °C
Storage temperature:
- 40 to + 70 °C
Relative humidity
of annual mean:
≤ 75 %
Altitude:
2000 m max.
Indoor use statement
4. Mounting
The SINEAX I 542 can be mounted on a top-hat rail.
Note "Environmental conditions" in Section
"3. Technical data" when determining the place
of installation!
I
N
0
0
Meas. input
0.9
1
N
1.1