Télécharger Imprimer la page

Marklin Digital mLD3 Mode D'emploi page 28

Publicité

Configuration Variables (CV). Reading the CVs is not possible.
• The CV numbers and the CV values are entered directly.
• Program the CVs only on the programming track.
• The default settings (factory settings) can be produced
repeatedly.
• 14 or 27 speed levels can be programmed.
• The first four functions and the lights can always be con-
trolled by means of the first address; additional functions can
be used, depending on the consecutive addresses.
• All of the settings from the function mapping for mfx or DCC
programming are taken on for fx (Motorola).
• Automatic recognition corresponding to the active additional
or consecutive addresses. What is recognized is whether
the function can be turned on or off continuously by means
of a consecutive address. This function mapping can only be
determined in the mfx or DCC protocol.
• See the CV description for the fx protocol for additional
information.
DCC Protocol
Addresses
• Short address – long address – multiple unit address
• Address range:
1 - 127 for short address and multiple unit address,
1 - 10239 for long address
• Every address can be programmed manually.
• A short or a long address is selected using the CVs.
• A multiple unit address that is being used deactivates the
standard address.
28
Programming
• The characteristics can be changed repeatedly using the
Configuration Variables (CV).
• The CV numbers and the CV values are entered directly.
• The CVs can be read and programmed repeatedly. (Program-
ming is done on the programming track).
• The CVs can be programmed in any order desired. (Program-
ming can be done on the main track PoM). The PoM can only
be done with those designated in the CV table. Programming
on the main track PoM must be supported by your central
controller (Please see the description for this unit).
• The default settings (factory settings) can be produced
repeatedly.
• 14/28 or 126 speed levels can be set.
• If automatic recognition in braking areas is to be used, we re-
commend shutting the DC operation off (see CV description).
In DCC operation setting the value in CV 27 to 16 or 32 (see CV
table).
• All of the functions can be controlled according to the func-
tion mapping (see CV description).
• See the CV description for the DCC protocol for additional
information.
We recommend that in general programming should be done on
the programming track.

Publicité

loading

Ce manuel est également adapté pour:

6097260982