RS 600 MW
Failure
Fan is not operating
Machine operates noisily
Unstable and / or non-adjustable
welding current
Heater outlet is not operating
4.4 Fuses
F1
Fuse
F2
F3
F4
4.5 Error Codes
Error Code
Error
E01
Thermal
Protection
Temperature Sensor
E05
Reading Error
www.magmaweld.com
• The fuse has blown
Reason
• Fan motor failure
• Contactor failure
• Diode group failure
• The fuse has blown
10 A
Amperage
1 A
1 A
1 A
Cause
• The uptime of your machine may have
been exceeded
• Fan may not be working
• The front of the air inlet-outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• There may be a hardware error
Maintenance and Service
• Check the fuse
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Check the fuse. Contact the
authorized service
Fast
Motor and Card of the Wire Feeder
Feature
Protected Circuir
Delayed
Fast
Fast
Card of Voltmeter / Ampermeter
• Allow the machine to cool down by
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
• If the problem continues, contact the
authorized service
• Check visually whether the fan is
working or not
• If the problem continues, contact the
authorized service
• Open the front of the air ducts
• If the problem continues, contact the
authorized service
• Make sure that the working
environment of the machine is not
excessively hot or stuffy
• If the problem continues, contact the
authorized service
• Contact the authorized service
29
Solution
Cooler Fan
CO2 Heater
Solution
USER MANUAL