NOTA :
The information given in the table below is a function of the quality of the water to be treated and
its evolution over time, the typology of the location of the appliance, processes upstream or downstream,
it can it is necessary to provide more maintenance at different times.
Item (1)
Action
1
Salt recharging
2
TH analysis upstream
TH analysis
3
downstream
Chloride analysis
4
upstream (after rege-
neration)
Chloride analysis
5
downstream (after
regeneration)
6
C
Regeneration test
7
C
Sealing control
Replacing filter of
8
C
electro-distributor
Internal checks of the
9
C
valve and cleaning
10
C
Programming check
Utilisation AQACLEAN
11
C
CT
12
Cleaning the salt tank
Replacing the brine
13
C
intake tubing
14
C
Replacing pilote valve
Replacing inlet and
15
C
outlet valves
16
C
Replacing brine valve
Replacing electro-dis-
17
C
tributor
Replacing the Inlet
18
and Outlet hoses
(1) - Our BWT regional offices are at your disposal to offer you, if you wish, a technical support contract tai-
lored to your device.
Technical manual BWT PERLA PRO XXL - code P0011058 - Rev 10 - 23/11/2021
48
Frequency
Comment
Depending on the consump-
weekly
tion of softened water
monthly
The periodicity can be
compared according to the
criticality of downstream
devices
quarterly
Half-yearly
The frequency can be
shortened according to the
quality of the water to be
treated.
The frequency can be
shortened according to the
Yearly
quality of salt used and the
water consumption.
Every 2
years
The frequency can be
shortened according to
the pressure, quality of the
water and the number of
Every 3
regenerations.
years
Every 4
years
References of spare parts or
consumables
Analysis kit P0001561A
Analysis kit (2 à 60 ppm)
P0029860 or strips (30 à
600 ppm) P0005030
P0003735 (x4)
Depending on the softener
Tubing 11x14 (meter)
P0090365
4 x P0012635
2 x P0012636
2 x P0011546
P0014822
P0019016