Clearance from
WATER
ceiling 800mm
Unit A5X
Control
NOTA :
Installation of a filter upstream of the softener is strongly recommended. For the regeneration
water, maximum height 3.00 meters. Foresee a regulatory load break, the pipe of the water of regenera-
tion must be fixed firmly without breakage.
A
Type
Ø body
Inlet/Outlet
150
575
300
615
400
780
600
935
800
1085
1250
1205
In millimeters
CAUTION :
In order to allow maintenance operations safely it is the customer's responsibility to provide
sufficient clearance on the sides of the device in order to set up a means of access (type PIR / PIRL or
equivalent) for to intervene on the upper part of the device.
Also provide a lifting ring capable of supporting at least a 50 kg load so that if necessary a lifting device
(hoist type or similar) can be installed to remove the hydraulic control block.
DIMENSIONS
RAW
SOFTENED
WATER
Power supply 230 Volts 50/60 Hz
Softener
A
B
Entr'axes
total height
Min/Max
145
1970/2000
145
2205/2235
145
2350/2380
145
2425/2455
145
2305/2335
145
2425/2455
Technical manual BWT PERLA PRO XXL - code P0011058 - Rev 10 - 23/11/2021
Inlet / outlet apertures
2''1/2 gas (66/76)
Towards drainage apertures threaded
1''1/4 gas
Salt tank overflow (gravity flow)
Salt tank
D
C
height to
Inlet/Outlet
drain pipe
Min/Max
Min/Max
1890/1920
1810/1840
2125/2155
2045/2075
2270/2300
2190/2220
2345/2375
2265/2295
2225/2255
2145/2175
2345/2375
2265/2295
E
F
E
height
Ø brine tank
brine tank
720
1435
820
1435
820
1435
1300
1570
1300
1570
2x1300
1570
31