OPTIONAL ACCESSORIES
The following items may be purchased separately: Extra receiver-collar, extra
wire, wire splices, transmitter, transmitter power adapter, receiver-collar charger,
contact points. To purchase accessories, please contact a Dogtra dealer, visit
Dogtra's online store at www.dogtra.com or call customer service at
1-778-956-7922.
Transmitter Power
Adaptor (24Volt 500mA)
Adapter Info
Manufacturer : E-SUN
Manufacturing country : CHINA
Model name : MKC-0501000S, MKC-2500500S
INPUT : 100-240V~50/60Hz 0.4A
OUTPUT : 5V 1000mA, 25V 500mA
Attention!
The unit must be close to the wall outlet and the wall outlet must be easily
accessible for security reasons.
26
Receiver/Collar Charger
(5Volt 1A)
TROUBLESHOOTING GUIDE
1. Dog Does Not Respond to Stimulation
- Adjust the collar fit.
- Trim the dog's hair or use longer contact points to make better skin contact.
- Recharge the battery in the receiver/collar.
- Adjust the stimulation intensity level.
2. System Test Procedures:
Whenever you experience a malfunction, you will need to do a test loop to
determine which component - collar, wall transmitter or yard wire - is not
working. Follow these steps to perform the test loop procedure.
1. Make a test E-Fence using at least 3 m to 6 m of fencing wire (or use the
ground wire).
2. Remove the existing boundary wire from your wall transmitter.
3. Insert the two ends of the test E-Fence wire into the wall transmitter.
4. Turn the field width adjustment knob to the 9 o'clock position or a low setting.
5. Place the test light on the receiver/collar. With the receiver/collar, approach
the test loop and note the distance between you and the wire when the collar
activates the test lamp.
6. Turn the field width adjustment knob to the 12 o'clock position or a medium
setting.
7. Back away from the wire and approach it again. Determine the distance
between you and the wire when the collar activates. The distance should be
greater on the medium range setting.
If more than one collar receiver is used, repeat the above test on each collar. If
there is no red light on the wire indicator light of the wall transmitter with the test
loop wire in place, the wall transmitter is malfunctioning. If the red light is solid
on the wall transmitter, but the collar does not activate on the test loop wire, the
receiver/collar is not working. Recharge the battery in the receiver/collar and
repeat the test. If the collars are activating normally, there may be a wire break in
the fence wire.
27