Technical Data
14.0 Technical Data
Display:
Reference-Range:
Temperature-Range:
Relative humidity:
Height above MSL:
Batterietype:
Current-consumption:
Batterie life:
Auto-Power-Off:
Data memory Interface:
Pollution degree:
Protection Category:
Overvoltage Category:
Dimensions:
Weight:
Voltage measurement Vac, Vdc:
Measurement Range Vac:
Measurement Range Vdc:
Resolution:
Tolerance:
Internal Resistance:
Frequency Measurement f:
Measurement Range:
Resolution:
Tolerance:
Voltage Range:
Insulation Measurement Rins:
Measurement Range:
Resolution:
Tolerance:
Nominal output voltage Un:
Nominal current In:
Short-circuit current Ik:
Max. open-circuit voltage:
Measurement time:
Number of Measurements:
Automatic measurement range selection
EUT automatically discharged after measurement
42
1 /2
3
digit or 3 digit LCD
+17°C to 27°C, max. 70% rel. humidity
0°C to 40°C
max. 80%
up to 2000m
6x 1,5V Mignon Typ IEC LR6 (size AA)
20mA (Stand-by)
for average use approx. 1 year
after approx. 5min
9600 Baud, 1 startbit, 8 data bits, even parity, 1 stoppbit
2
2, IP50
CAT III / 440V against ground
235 x 103 x 70 mm
650g incl. Batteries
1 ... 440VAC (Frequency f: 10 ... 99.9 Hz)
1 ... ±440VDC
1 V
±(3% rdg. ±+3 Digit)
280 kΩ
10,0 ... 99,9Hz
0,1Hz
±(1% rdg. +1 Digit)
5 ... 440VAC
0,05 ... 19,99MΩ, 20,0 ... 199,9MΩ
0,01MΩ, 0,1MΩ
±(5% rdg. 5 Digit)
500V dc
≥1mA at Un
approx.. 3mA
Un + 50%
1 - 3s (automatic)
1 - 10s (automatic, at capacitivety Load)
1600 (500kΩ, 1 measurement - 25s break)