2 P.E.
1 P.E.
a a
Programming the open-gate function
An operator control can be connected to the module relay and/or
an operator status to the door status input.
From applicable, preconfi gured internal receivers, the relay can be controlled using the open-gate command and/or the operator status
shown via the relevant LED on the internal receiver itself.
To confi gure the module with the open-gate function, enable the function on one of the connected internal receivers, by entering call
programming (see previous paragraph), and send an open-gate command from the internal receiver (press and hold the "key" button)
as an alternative to or in addition to associating the call button. The open-gate LED lights up on this internal receiver to indicate that the
function has also been enabled on the module.
The open-gate function can only be enabled on a module connected to BIN1 on the power supply.
☞
If the module is programmed with the open-gate function, the "door contact input" terminal will function exclusively as
an operator status indicator.
☞
This function is available from version 1.03.000 of the module software and version 1.08.000 of the power supply
software.
☞
You can force the switch from one programming mode to another by pressing the PROG button on the power supply unit
for 3 seconds and releasing within 6 seconds. If you force the switch to call programming from button programming, the
button units which have not been programmed are confi gured to 8 calls. If the basic module is not programmed, calls are
not confi gured.
<1''
<1''
A
2 P.E.
2 P.E.
2 P.E.
b b
PROG
PROG
M1
Programming buttons
Press the fi rst call button on each unit
section) until the blue LED
☞
The LED lights on the unit remain on to show that the
buttons have been programmed correctly.
☞
For the basic unit (no call buttons), you do not need to
press the buttons that are shown as fl ashing in fi gure
Repeat for all entry panels to be programmed. Once programming
is complete, confi guration
automatically taken to "programming calls".
Programming calls
The green LED
fl ashes. Lift the internal-receiver handset
(if present) and press the door lock release
buttons
. On the entry panel, press the call button to be linked
to the internal receiver
b b . End the call and repeat programming for
has been stored
all of the other internal receivers.
☞
The operation can only be carried out from the entry
panel with the blue LED
change the entry panel from which calls are programmed,
press one of the call buttons on the entry panel you wish to
use for programming.
Exiting programming
Press the PROG button briefl y
switch off .
(see "call number"
and the button LEDs stop fl ashing.
is implemented and you are
and AUX2
a a . A beep confi rms that the setting
off (1 entry panel in
>3''
. The LEDs on the entry panel
a a .
). To