Programming an intercommunicating group
Press and hold the PROG button on the entry panel for at least 8 seconds and release within 11 seconds
The red
and yellow
>20''
>20''
PROG
To enable the intercommunicating function, press the intercommunicating call button you want to call with on the internal receiver you
want to program
. A beep indicates that the function has been programmed successfully. Repeat for all of the other internal receivers
to be included in the intercommunicating group. To conclude programming, press the PROG button on the entry panel briefl y
☞
Once an internal receiver has been included in a group by assigning the intercommunicating call button, it cannot be
excluded from this group. If you want to change the call button on an internal receiver which has already been programmed
as an intercommunicating receiver, or you want to add new internal receivers to the group, repeat the operations detailed
under "Programming an intercommunicating group".
PROG
AUTOMATIC DOOR RELEASE function
For internal receivers that support the AUTOMATIC DOOR RELEASE function only.
This function is used to open the entrance automatically when there is a call from the entry panel. No communication is activated and
the call ends automatically.
☞
Follow the instructions in the internal receiver manual.
PROGRAMMING ENTRY PANELS WITH VA/01 OR A/01
Programming for the first time
PROG
PROG
>3''
>3''
a
a a
LEDs fl ash to show intercom programming is in progress
Entering programming mode
Press the PROG button on the power supply
The LEDs
M
programmed
a a
a
PROG
.
and
and the button LEDs fl ash to show the buttons are being
.
1 P.E.
.
>8''
>8''
PROG
<11''
<11''
<1''
<1''
PROG
until the PROG LED lights up.
1 P.E.
1 P.E.
.