Preparation
8.
Preparation
8.1
Installation site
f Always install the appliance in a room free from the risk of
frost and near the draw-off point.
f Ensure the floor is level.
f Ensure the floor has a sufficient load bearing capacity (see
chapter "Specification / Data table").
f Observe the room height and height when tilted (see chapter
"Specification / Data table").
Minimum clearances
The minimum side clearances can be swapped between left and
right.
≥100
≥500
f Maintain the minimum clearances.
8.2
Transport and handling
Material losses
!
We recommend leaving the transport packaging in place
on the cylinder for transportation to the installation site,
to prevent the cylinder casing from becoming dirty or
damaged.
In particular, the edge protection on the underside of the
appliance should only be removed after the appliance has
been sited and aligned.
Material losses
!
The hydraulic connections and installation components
can be damaged when the appliance is set down or car-
ried.
f Ensure that the flange is facing upwards.
For transportation, the appliance is secured to the pallet with
3 screws.
f Undo the screws from the pallet.
18
| SBB 300-1 Plus, SBB 400-1 Plus, SBB 500-1 Plus
≥500
≥100
f Tilt the appliance from the pallet onto a suitable support.
8.2.1 Carrying aids
To facilitate handling during transportation, you can fit carrying
aids to the top and bottom of the appliance.
Underside of the appliance
Material losses
!
Always use the supplied lifting straps in combination with
the supplied washers.
Note
The carrying straps are intended for one-time use to ma-
noeuvre the appliance.
SBB 300-1 Plus
1
2
1 Washer
2 Adjustable foot
3 Lifting strap
3