The spa is provided with a safety sign in the package. The safety
sign is suitable for outdoor use in wet locations and should be
permanent installed were visible to the users of the spa.
The installation of safety sign:
1. Take the safety sign out of package;
2. Fixed it to a place near the spa which users can read it clearly.
It is very important to provide warnings to occasional users of the
spa. Make sure the user are aware of the measures to reduce the
potential risks.
To obtain additional or replacement copies of the safety sign, please
contact qualified technician.
STEP 3 - Inflation and Deflation
1. Take out the Ground Cloth(B) and spread it over the cleared area.
Take out the Spa Tub Liner(C) from the storage bag and spread it
out over the ground cloth Point the drain valve towards a suitable
draining area.
2. Remove the 3 protective covers from the outer wall of the spa, and
cover the air outlet at the bottom of the Control Base(F) with one
cover. Prevent air leakage during inflation.
3. Flip the external control box, open the Blower Outlet Cap(H)c,
attach the Inflation Hose(G) onto the air outlet at the front side of the
Control Base(F). Tighten it in place (see below).
4. Unscrew the cover on the air valve cover on the outer wall of the
spa and directly insert one end of the inflation hose.
5.Turn on the power, turn on the "BUBBLE" button and start
self-inflation. During the inflation process, help the hot tub unfold.
Wait about a few minutes.
6. Remove the inflation hose, and close the air valve cover.
Note: Simply using the inflation hose to self-inflate, the spa is not
very full. Continue to use the hand pump to inflate the spa.
7. Connect the hose of the hand pump. Connect one end of the hand
pump to the air inlet of the spa. If the air valve cover is closed and
needs to be opened.
8. Observe the pointer change on the hand pump, ensure to the
green range.
9. After inflation is completed, remove the hose from the hand pump,
and close the air valve cover. Tighten it in place.
10. Install the 3 connecting tubes, and connect the 3 interfaces
between the Control Base(F) and hot tub wall.
Tighten the Blower Outlet Cap(H).
Tips: When draining, please use the Drainage Regulator (O).
Deflate: Open the air valve cover on the pool wall, press the yellow
button to release Air.
14
WARNING
Do not over inflate or
use high pressure air
compressor to inflate.
• Press the BUBBLE button to inflate the spa tub wall for 8 to 10
minutes until it is firm to the touch but not hard, the upper edge can
still be pressed in by the palm of your hand (appro.1.5 to 2 inches).
Then press the BUBBLE button again to stop inflating.
• Unplug the Inflation Hose(G) and tighten the one way valve kit.
Inflate the Spa Cover Air Bladder(E).
• Plug the Inflation Hose(G) directly into the air valve on the spa
cover air bladder, no need to use the 3 spare nozzles attached.
• Press the BUBBLE button to inflate until it is firm to the touch but
not hard.
• Once inflation finished. Press the LOCK icon to unlock the control
panel. Then press the BUBBLE icon to stop inflation.
Remove the Inflation Hose(G) from the air outlet on the Control
Base(F). Reinstall the Inflation Outlet Cap(H) back onto the Control
Base.
NOTE:
1. Whistling sound occurs if bubble function activated before inflation
hose plugged into the one way valve kit. This is normal not quality
issue.
2. To expedite the inflation process, cover the bubble air outlet (the
bottom one of the 3 outlets on the Control Base) with the inlet
protective caps on the SPA exterior wall.
3. DO NOT over inflate. If the Spar Cover Air Bladder cannot fit into
the Spa, it might be over inflated. Deflate to let some air out. And it
will fit.
4. If you want to add air to a spa filled with water, press the BUBBLE
button and wait 4-5 minutes. Then redo the inflation as described
above.
15