Free chlorine
pH
Total alkalinity (TA)
Calcium hardness
(CaCO3)
Active oxygen
Bromine
WARNING
DO NOT add chemicals if the spa is occupied.
DO NOT add water to chemical but add chemical to water.
DO NOT let chlorine come in contact with the spa tub if it is
not completely dissolved.
Filter Cartridge Maintenance.
To ensure your spa water stays clean, check and clean your
filter cartridges every day.
1. Unscrew the filter assembly from the spa tub wall and remove the
cartridge.
2. Use a garden hose to rinse off the cartridge. If the cartridge
remains soiled and discolored it should be replaced. Keep spare
cartridges on hand.
3. Attach the filter cover onto the clean cartridge and replace the
cartridge assembly back onto the spa tub wall.
26
Minimum
Ideal
Maximum
2 ppm
2-4ppm
5 ppm
7
7.2- 7.6
7.8
60 ppm
80 ppm
120 ppm
100 ppm
150-250 ppm
350 ppm
5 mg/|
6- 7 mg/l
8 mg/l
3 mg/I
3.5- 4.5 mg/l
5 mg/1
WARNING
Always unplug this product from the power supply before removing,
cleaning, servicing or making any adjustment to the product.
Spa Cover Maintenance
The cover shall be cleaned inside and out periodically using a
suitable solution that includes adequate disinfection (e.g. 10 mg/l of
Free Chlorine).
To assure safety from unauthorized access, always put the cover on
when spa is not in use and lock all buckles.
Always keep the keys out of reach of children. In case you misplace
the keys, you can use any similar size flat screwdriver to lock or
unlock the buckles.
SPA Tub Repair
If the spa is torn or punctured, use the provided PVC Repair
Patch(N) and glue (not included) :
1. Clean and dry the area to be repaired.
2. Cut the provided PVC patch to appropriate size.
3. Use glue (not included) to coat the one side of the newly cut
patch. Make sure the glue is evenly distributed.
4. Wait for 30 seconds(or refer to the glue manufacture instructions)
and then place the cut patch with glue over the damaged area.
5. Smooth out any bubbles of air that may be trapped underneath,
and press firmly for two minutes.
6. The product is once again ready for use. Repeat this process
should further leaks occur.
7. Wait 30 minutes before inflation.
27