WARNING
Risk of fire:
This product draws a current of 12 AMPS. It is suggested to provide
a exclusive circuit breaker to feed the spa ONLY, rated at least 15A.
Otherwise, please make sure the circuit breaker fits well with all the
appliances connected and won't trip. Never use an extension cord.
Unfold the line cord prior to use.
Never place the plug on combustible materials.
Note: the spa equipment features a complete grounding system that
is also in contact with the spa water. It is possible that a person may
build up static electricity that discharges when touching the water.
Regardless, any electric shock experienced should be investigated
by a qualified electrician prior to use of the spa. Unplug the spa until
the cause is determined and any corrective action completed.
Control Panel (display)
Once plugged into the power supply (GFCI on TEST/ON), the
control panel will light with a beep. Then the LED screen will read
the current water temperature in the spa.
20
TEMP UP/DOWN
• Temperature set: After startup, press TEMP UP or TEMP
DOWN to set the desired temperature(LED display reads
will flash). Wait for 5 seconds without further operation, the
temperature set is done.
After desired temperature set, press the HEATER button to
start heating.
Note: Temperature can be set from 68℉(20℃) to 104
℉(40℃). The Default temperature is set at 100℉/38℃.
• Enter FP(Freeze Protection) mode( see below FP mode
description as below.
LOCK
The spa is designed with child lock function to prevent
improper operation, especially child misusing.
• If no more operation in 10 seconds, the control base will
enter the LOCK mode. In this case all the other buttons will
not work.Press the LOCK button to quit the LOCK mode
before proceed any other operation.
• To enter the LOCK mode manually, just press the LOCK
button.
HEATER
Press this button to activate the heating system. The
pump will heat the spa water until the water temperature
reaches the set temperature. When the spa water
temperature drops around 3.6℉(2℃) below the set
temperature the heating system will restart.
Note: If the heating system is activated, the filtration
system will automatically start.