Work stations
The tool is intended to be operated as a hand-held tool. It is always recommended that the tool should be used when
standing on a solid floor. It can be in any position but before any such use, the operator must be in a secure position,
having a firm grip and footing and be aware that the sander can develop a torque reaction. See the section Operating
instructions .
Operating instructions
When unpacking the tool, make sure it is intact, complete and has not been damaged in transport. Never use a damaged
tool.
To attach air supply, lift up the cover and connect air supply, close the cover before operating the tool. Use a clean
lubricated air supply that will give a measured air pressure at the tool of 6.2 bar (90 psig) when the tool is running with
the lever fully pressed. It is recommended to use an approved 10 mm (3/8") x 8 m (25 ft) maximum length air hose. The
tool should be connected to the air supply as shown in Figure 1.
Do not connect the tool to the compressed air system without incorporating an easy to reach and operate air shutoff
valve. It is strongly recommended that an air filter, regulator and lubricator (FRL) are used as shown in Figure 1 as this
will supply clean, lubricated air at the correct pressure to the tool. Details of such equipment can be obtained from your
supplier. If such equipment is not used the tool should be manually lubricated.
To manually lubricate the tool, disconnect the air hose and put 2 to 3 drops of oil, Wurth art. no. 08930505 into the air
connection on the tool. Reconnect the tool to the air supply and run the tool slowly for a few seconds to allow air to
circulate the oil. If the tool is used frequently, lubricate it on a daily basis.
Lubricate the tool before longer storage or if the tool slows down or loses power.
It is recommended that the air pressure at the tool is 6.2 bar (90 psig) while the tool is running. The tool can run at lower
pressures but never higher than 6.2 bar (90 psig).
Figure 1
Maintenance
Always disconnect the air supply before maintenance!
Only use original Mirka spare parts!
Filter
Regulator
Lubricator
Air hose to your power tool