Télécharger Imprimer la page

Seca 727 Mode D'emploi page 5

Masquer les pouces Voir aussi pour 727:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
www.mirvesov.ru
Preparation is important...
Transport locking device
Loosen transport locking device. First turn over
the scales so that the baseplate is at the top.
Loosen the two outer clamping screws (1). Pull out
the spacers (3) between the frame (5) and the cra­
dle support (2) sideways and remove the clamping
bar (6) with the screws and spacers.
Note: Before transporting over long distances, the
scales must be locked again by re­inserting the
spacers and tightening the clamping screws hand
tight. Therefore keep the transport locking device
and packaging.
6
5
1
2
3
1
2
Model 728
3
Power supply
The scales can be either mains or accumulator
operated. A power supply unit and a set of accu­
mulators are supplied; both parts are connected
by the following procedure. You can then choose
between mains and accumulator operation.
Mains and accumulator operation
Insert the low voltage plug of the plug­in power
supply unit provided into the low voltage socket (9)
of the baseplate.
www.mirvesov.ru
Press lock (8) in the cover of the battery compart­
ment towards the text "BATTERY" and open
the cover. Then insert the plug (7) of the set of
accumulators (10) into socket (11). Insert the set of
accumulators in the battery compartment, close
the cover again and engage the lock.
Note: For weighing independently of the mains,
the set of accumulators must be charged up
before initial use by plugging the power supply unit
into the scales for 24 hours.
Connect the plug­in power supply unit to the
mains.
7
4
4
Model 727
6
5
4
How to weigh correctly...
Press the green start button (13).
appears in sequence on the display (16).
The scales are ready for operation. Zeroing takes
place automatically when the scales are empty.
However, if a value other than
the display, the start button (13) is to be pressed
for zeroing prior to weighing. The empty scales
switch off after 10 minutes when mains operated,
and after one minute when accumulator operated.
Before using the scales for further weighing, the
start button must be pressed again and
awaited.
Компания "Мир Весов"
8
10
9
11
and then
appears on
Компания "Мир Весов"
Тел.: (495) 921-44-57
With accumulator operation,
the display if the accumulators have to be re­
charged. This happens automatically by connect­
ing the plug­in power supply unit provided.
Model 727
Model 728
If scale is switched on
weights up to 0,4 kg will
be tared, more than 0,4
-Tare
kg will be stored by pushing
the 'Net/HoldButton'.
-Hold
-lbs:oz
(blinking)
17
16
15
Changeover kg/lbs
If you require the weight to be displayed in lbs,
press the kg/lbs changeover switch (14) after
switching on or while weighing. The lbs indicator
(15) lights up for the lbs setting.
On scales with the Autohold function
The Autohold function is intended to save the user
pressing the Hold key.
It is active as soon as the scale is switched on.
If a load of over 400 g is placed on the scale, the
weight is automatically held in the display.
Pressing the Hold key releases the weight from
Hold.
The Autohold function only becomes active again
when a load of over 400 g is placed on the scale.
This procedure can be repeated as often as
required.
Тел.: (495) 921-44-57
appears on
16
4
14
13
12
5

Publicité

loading

Ce manuel est également adapté pour:

728