Install with the lowest possible air resistance and free of leakage. Minimise
AIR DUCT
the use of flexible pipes.
CONNECTIONS
DISCHARGE CONNECTION
The suction connections must be opened according to use and position. At
the rear, an intake connection of up to Ø270 mm can be provided. In the
latter case, the use of a sealing ring (not supplied) is recommended.
ELECTRICAL
The ventilation unit must be connected in accordance with the standards
and locally applicable regulations. Supply voltage 230V±10%, single-phase,
CONNECTION
50Hz.
All C400 ventilation units are equipped with a cord with a standard edge-to-
earth plug for electrical connection.
Do not plug in until all parts of the ventilation system have been installed.
THREE-POSITION SWITCH C400
Three ventilation speeds can be selected with this type of switch. Before
you wish to connect the position switch, unplug it. The unit's electronics
are located behind the front plate of the fan housing. Click off the front
cover plate. There are two screws behind the cover plate. Remove the two
screws and tilt the cover downwards. The electronics are now freely
accessible.
Ø150
Ø125
INSTALLATION MANUAL FOR THE INSTALLER 07