04 USER MANUAL
CO
RF switch
2
The ventilation unit is expandable with a CO
choose a fixed flow rate or a flow rate according to your needs. By touching
the control area at the bottom several times, you can scroll between the
different modes. The LED at the top right indicates the mode.
Position
positio
n 1
(low)
position 2
(middle)
setting
3 (high)
eco mode
comfort
setting
RH RF switch
The ventilation unit is expandable with an RH RF switch that temporarily
boosts the ventilation flow rate when you take a shower, for example. By
touching several times on the control area at the bottom, you can scroll
between the different modes. The LED at the top right indicates the mode.
Position
positio
n 1
(low)
position 2
(middle)
setting
3 (high)
autostand
medium
autostand
maximum
2
Description
Vasco recommends using this mode during absences.
This is the default position during presence.
This is the recommended setting when showering and
bathing. Can also be used when there is an increased
need for ventilation (v i s i t o r s , family parties, etc.).
In this automatic mode, the ventilation unit adjusts the
ventilation rate according to the number of people in the room
where the switch is set up. At this setting, minimum indoor
air quality is guaranteed to save maximum energy. Vasco
recommends using this setting in winter periods.
In this automatic mode, the ventilation unit adjusts the
ventilation rate to the number of people in the room where the
switch is set up. This control guarantees you a higher indoor
air quality. Vasco recommends using this setting in summer
periods.
Description
Vasco recommends using this mode during absences.
This is the default position during presence.
This is the recommended setting when showering and
bathing. Can also be used when there is an increased
need for ventilation (v i s i t o r s , family parties, etc.).
At this setting, the air flow rate remains fixed at the flow rate
corresponding to the last ventilation setting selected. In case of
a sudden increase i n relative humidity (showering), the
ventilation unit automatically switches to the middle setting.
At this setting, the air flow rate remains fixed at the flow rate
corresponding to the last ventilation setting selected. In case of
a sudden increase i n relative humidity (showering), the
ventilation unit automatically switches to the high setting.
RF switch that allows you to