MOUNTING RH RF SWITCH
Always mount the RH RF switch in an easily accessible place in the
bathroom.
1
2
3
4
Step
As standard, the switch supplied ex-factory is linked to the ventilation unit. In
CONNECTING
total, up to 20 switches can be linked to the system.
SWITCHES
LOGGING ON AND OFF ADDITIONAL OPTIONAL RF POSITION SWITCH
Log on: Unplug the ventilation unit and reinsert it. After this, the ventilation
unit will search for new switches for 10 minutes. Press the button of stage 2
and timer simultaneously for at least 3 seconds. If the pairing operation is
successful, the LED in the middle will light up green twice.
Tip: You can link one switch to a maximum of 3 units. To do so, follow the
actions above for each switch. When pairing, make sure that only one
ventilation unit is energised or that the other units nearby are energised for at
least 15 minutes.
Logging off: Unplug and reinsert. The ventilation unit may disconnect
switches for 10 minutes.
Press the button of position 1 and 3 simultaneously for a minimum of 3
seconds. The switch LED lights up orange 2x to indicate that the switches are
disconnected.
Dismantle the switch.
Mark out the screw holes of the base plate on the wall.
Screw the base plate to the wall.
Replace the cover on the switch.