Télécharger Imprimer la page

RIB BOSS 230V MASTER DX Instructions De Montage page 54

Publicité

Les langues disponibles

Les langues disponibles

G
PROGRAMMING
B
B - SETTINGS
SYSTEM MICROSWITCHES
DIP 1 Single pulse contact (K, K COVER and RADIO) stepper (ON) - automatic (OFF)
DIP 2 Photocells permanently enabled (OFF)
Photocells enabled only during closure (ON)
DIP 3 Encoder (ON - enabled)
DIP 4 Release device priming (ON - enabled)
DIP 5 Pre-signal warning light (ON) - Normal warning light (OFF)
DIP 6 Safety strip monitoring TEST (ON enabled, OFF disabled)
DIP 7 Radio system enabled (Lithio ON, Moon OFF)
DIP 8 Motor direction of rotation control function (ON) (POINT C)
JP1 => Remove all radio codes
JP2 => Encoder used as crush prevention safety (jumper closed)
LED WARNING SIGNALS
DL1
Radio programming (red)
DL2
Radio programming (green)
DL3
Safety strip contact (NC) (red)
DL4
Photocell contact (NC) (red)
DL5
Command button control (NA) (green)
DL6
Up-and-over door closing (red)
DL7
Up-and-over door opening (green)
DL8
Encoder operations control (red)
DL9
Automatic closing time signal (red)
C - MOTOR DIRECTION OF ROTATION CONTROL FUNCTION
This control function facilitates operations when the system is being installed and
successive tests and controls.
1 - Set DIP 8 to ON. The DL1 LED lamp begins to signal.
2 - Press, and keep pressed down, button S1-PROG. (movement will now be performed
in dead man's switch mode; open-stop-close-stop-open-etc.) => The DL7 green LED
lamp is activated, the door opens and comes to a halt when contact is made with the
closing stop limit switch.
3 - Press, and keep pressed down, button S1-PROG. => The DL6 red LED lamp is
activated, the door opens and comes to a halt when contact is made with the closing
stop limit switch.
4 - Adjust the electric control limit switch in order that the up-and-over door stops in
proximity to total opening or closing.
5 - Carry out force regulation using the trimmer TORQUE (VR2) to select the required
speed.
6 - Turn DIP8 to OFF when trimmer adjustment and control operations have been carried
out. The DL1 LED lamp will be deactivated to signal the termination of control
operations.
N.B.: During checking and controlling operations, the remote control, safety
strips and photocells are not activated.
D - AUXILIARY COMMAND FUNCTION OPERATIONS
SINGLE PULSE K (terminals 1-2) CONTROL SWITCH
When DIP1 is set to ON =>
When DIP1 is set to OFF =>
CLOCK FUNCTION
(Only in DIP1 OFF automatic mode)
This function is useful during peak hours or when traffic is slowed down (e.g. workers
entering/exiting worksite, emergency situations in residential or parking zones, or
temporary obstructions due to removal services).
IMPLEMENTATION
By connecting a switch and/or day/week type clock (in place of, or parallel to, the
control button for N.O. 1-2 terminals, it is possible to open the door, and keep
Carries out a cyclic control of command functions;
open-stop-close-stop-open etc.
Carries out opening operations with door in closed
position. If activated during opening, the operation
will not take place. If activated when the door is open,
this command will close it; if activated during closing
operations, this command will reopen it.
the door open, until the switch is pressed down, or while the clock is activated.
All command functions are disabled when the door is in an open position.
When the switch is released or the preset clock time expires, the door closes immediately.
K COVER CONTROL BUTTON
(Terminals 13 and14)
The control button is located on the casing.
When DIP1 is set to ON =>
When DIP1 is set to OFF =>
It can be used for radio code programming procedures.
REMOTE CONTROL
When DIP1 is set to ON =>
When DIP1 is set to OFF =>
E - AUXILIARY SAFETY DEVICE OPERATIONS
ENCODER
It is applied on the motor and its correct functioning is signalled by led DL8 that flashes
during movement.
If DIP 3 is ON => IT ONLY WORKS AS A POSITION MEASUREMENT TO START
SLOW DOWN
It is active opened and closed to determine the correct slow down start point in closure.
If DIP 3 is ON and JP2 is closed => IT WORKS AS CRUSH PREVENTION SAFETY
If the oscillator encounters an obstacle, the encoder inverts movement both during opening
and during closure. Remember that, in compliance with standards in force, it is equally
necessary to conduct the impact tests using the specific tool.
SAFETY ENCODER ALARM
If there is a second successive action following any initial activation of the opening or
closing of the Encoder like safety (obviously in the opposite direction to the initial action) the
up-and-over door stops for 1 second and reverses the original requested movement- as
required by European legislation currently in force.
The alarm is displayed by the warning light, which remains active for one minute, and the
flashing courtesy light. During this time, it is possible to restart the up-and-over door by
pressing any control button.
ALARM FROM OUT OF ORDER ENCODER
In the event of encoder failure or breakdown, the motor stops all operations, both flashing
lamp and courtesy light blink on and off constantly to signal alarm status and the DL8 LED
lamp remains switched off.
PHOTOCELL (terminals 3 and 4)
DIP 2 OFF =>
When the door is closed, it will not open if there is an object within
the range of the photocells. During working operations, the photocells
are active both during opening (with resetting of motor during opening
operations only when the obstacle is removed) and during closing (with
resetting of motor in reverse only when the obstacle is removed).
DIP 2 ON =>
When the door is closed, it will open if requested to do so even if there
is an object within the range of the photocells (the photocells remain
inactivated during opening). Photocells will become enabled only in the
event of door closure (with reverse motor resetting after a 1-second
interval, even with photocells enabled).
NOTE: if this auxiliary device is not used, create a jumper
between terminals 3 and 4.
ATTENTION: In case the receiver led remains lit,
malfunctioning of the main supply is suspected. It is
advisable to connect electrically to earth the columns
or the photocells stands to the terminal 10, to shield
the photocells from external noise.
54
Carries out a cyclic control
of command functions; open-
stop-close-stop-open etc.
Carries out opening operations
with door in closed position. If
activated during opening, the
operation will not take place. If activated when the
door is open, this command will close it; if activated
during closing operations, this command will reopen it.
Carries out a cyclic control of command functions;
open-stop-close-stop-open etc.
Carries out opening operations with door in closed
position. If activated during opening, the operation
will not take place. If activated when the door is open,
this command will close it; if activated during closing
operations, this command will reopen it.
24V AC
Term.
10

Publicité

loading

Ce manuel est également adapté pour:

Boss 230v serieBoss 230v master sxAa40834Aa40833