A - CONNEXIONS
LINE EARTH
J1
10
9
J12
S1
TF
J7
24
23
22
21
20
19
J5
18
17
J6
MOTOR EARTH
J3
J2
8
7 6
5
4
3
2
1
JP
1 - 2
14
13
12
11
15
J4
16
VR2
VR1
J11
J8
J9
J10
J1
L-N
230Vac 50/60Hz power supply
J2
1
Single pulse contact (NA) K
2
Common to contacts
3
Contact for photocells (NC)
4
Common to contacts
5
Facet contact (NC) - for opening and closing interventions
6
Common to contacts
7
Common to contacts
8
A* TEST - 24 Vac facet auto-test power
9
A* - 24Vac accessory power
10
A - 24Vac common accessory power
J3
11
Flashing lamp power supply (24 Vdc)
12
Not connected
13
K Cover single pulse contact (NA) on flashing lamp
14
Common to contacts
J4
15
Antenna cable earthing
16
Antenna cable central wire
J5
17
Signal light 230V40 W max
18
J6
19 V1
MASTER opening phase motor
20 U1
Common MASTER motor
21 W1
MASTER closing phase motor
J7
22 V2
SLAVE opening phase motor
23 U2
Common SLAVE motor
24 W2
SLAVE closing phase motor
J8
CAP
Connector for MASTER motor condenser
J9
LSC
Contact for closing stop limit switch
LSO
Contact for opening stop limit switch
COM
Common to contacts
J10
ENCODER S
Connector for encoder - green wire (signal)
ENCODER +
Connector for encoder - brown wire (+ 5 v)
ENCODER -
Connector for encoder - white wire (earthing)
J11
RADIO
Built-in radio module
DO NOT TOUCH THE JUMPER! THE OPERATOR IS
J12
DISABLED IF THE JUMPER IS REMOVED!
VR1
TRIMMER TCA
Trimmer for automatic closing time adjustment. DISABLED
DEFAULT AND DL9 LED OFF
VR2
TRIMMER
Trimmer with force electronic regulation
TORQUE
JP1
Activation of radio code clearing
JP2
Encoder enabling with crush prevention safety (active if
closed)
P1
S1-PROG.
Programming control lever
F1
T 5A
Fuse to protect network and motor power
F2
T 0,1A
Fuse to protect secondary circuit
53
G
B