Télécharger Imprimer la page

Fagor LAP-08 Manuel D'utilisation page 34

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 103
5
MAINTENANCE
5.1 Electrical and mechanical irregularities
Before calling the Technical Service Centre, check the following:
That power is supplied to the machine.
The condition of the fuses.
That the voltage is correct for the machine.
If the washing machine fails to get the required level of water, check:
The water mains tap is open.
The water inlet filter is not blocked.
That the water pressure is between 2 and 4 kg/cm 28 (28 and 56 psi).
If the washing machine vibrates excessively, check that none of the panel screws is loose.
If a power cut occurs, check that the tub is drained and the door is blocked. If you want to take the clothes out
of the washing machine, unlock the door by pulling down the belt located behind the front panel.
5.2 Warnings
All warnings and errors are reported on screen together with an acoustic alarm. In the event of an error, the
cycle and status information is maintained in order to determine exactly where the error has occurred.
The following warnings may be found in a washing machine:
DESCRIPTION
OPEN DOOR
WATER IN TUB
NO COMMUNICATION
BETWEEN CARDS
FULL TANKS (T1/T2/T3)
EMPTY TANKS
(T1/T2/T3)
NO COMMUNICATION
WITH WEIGHING KIT
30
CAUSE AND ACTION
If the door is open at the start of a programme, the message "DOOR OPEN" is displayed on
screen and the buzzer will buzz for 30 seconds and no more.
Only the option "OK" is given. The programme will not start and the user can try again.
At the end of a programme, if the water level is not 0 mm, the message "WATER IN TUB" is
displayed on screen.
The 2 options "continue" or "end" are displayed. If we press "continue" the machine checks
again for a level of 0 mm. If this is the case, the door is unlocked, if not the error is reported
again. If we press "end", the programme will end and the door unlocks.
In the SAT menu, in the Extra Kit section, on activating a kit, if no communication is detected
between the principal control card and the auxiliary card, this warning is displayed.
Active kits without communication between cards can be deactivated, but they cannot be
activated.
This warning is displayed when Tank Tx is active in a drainage cycle and the input "Max level
Tank x" is found to be activated.
The machine stops draining to Tx and switches to normal drainage D1. Buzzer is activated
for 10 seconds. The warning disappears on pressing OK or after a certain time interval.
This warning is displayed when Tank Tx is active in a fill cycle and the input "Min level Tank
x" has been activated.
The machine stops filling from Tx and switches to filling normally with cold water. Buzzer is
activated for 10 seconds. The warning disappears on pressing OK or after a certain time
interval.
This warning is displayed if, on activating the weighing kit or making a calibration, the
auxiliary card is connected and operating correctly, but it is not possible to communicate with
the weighing appliance.
It is not possible to activate the kit or make the calibration.

Publicité

loading