Télécharger Imprimer la page

Assa Abloy KESO Integra Notice D'installation Et De Montage page 60

Masquer les pouces Voir aussi pour KESO Integra:

Publicité

Les langues disponibles

Les langues disponibles

EN
60
Problem, cause, solution
No response to activation signal
Symptoms
Function LED does
not light up
The function LED
flashes quickly
(5 Hz)
The function LED
flashes slowly
(1 Hz)
Reader is not
working
Yellow LED does
not light up when
KESO Reader is
connected
Possible cause
· Power supply input not
connected
· Power supply input is
connected with reverse
polarity
· Short circuit at VDC out
· Electronics are neutral or
faulty
- Delivery continuously
open
· No voltage at the Reader,
LEDs on the Reader do not
light up
· Switch position on the
Reader is wrong
· Reader wired wrongly
· Reader firmware is not
up-to-date
Remedial measures
· Check the power supply
input with a voltmeter.
· Unplug VDC out
· Fit new electronics
· Program the system data
· Check the switch at the
Reader
· Check the wiring
· Unplug the KAPI

Publicité

loading