KESO Integra Door Controller
Characteristic
Power supply
Supply voltage
Power consumption
Residual ripple
Distance with
central power supply
Terminals
Ethernet
Programming interfaces
Door monitoring
Outputs
Status indicators
Temperature and moisture
Protection category
Operating temperature
Storage temperature
Air humidity
Standards
Feature
Stabilised mains adapter 12 V DC / 24 V DC in
accordance with
EN610000-3-2
EN61000-6-2
12–24 V DC / +/–10%
1 W, maximum, including network module.
Without external components such as readers and relay
Without VDC out
Type 0.06 A at 12 V DC
Type 0.05 A at 24 V DC
300 mVpp, maximum
100 m, maximum
Plug-in screw terminals
(protected against reverse polarity)
RJ45 with integrated LED (yellow/green)
10/100 Mbps Ethernet interface
DHCP, Dynamic IP
EN55022 and EN55024
USB for
- KESO Integra programming device V3
- Firmware update
Firmware version 10.0.0.x and later
Relay (external devices)
Inputs, relays, operating status with LED
IEC 68-2-1 / 2 / 3 / 14
IP20 (AP housing)
0 °C – +50 °C
–40 °C – +90 °C
10 % to 95 % (non condensing)
EN610000-3-2
EN61000-6-2
53