Tab. 1 :
KESO Integra Door
Controller specific
settings
EN
48
Setting in operation
Programming the KESO Integra Door Controller with
KESO k-entry
®
The KESO Integra Door Controller is programmed using the k-entry
management software in combination with the KESO programming device V3.
Settings specific to the KESO Integra Door Controller can be set using the k-entry
KESO management software (Properties – KEK header) (Tab. 1):
Description
1
Continuously
open
2
Open with pow-
er fail
3
Unlocking time
4
Use the «Office/
Shop function»
5
Deliberate action
required
(Not available for
Aperio™)
6
Door monitoring This function is only active via the KESO Integra Door
Function check of the KESO Integra Door Controller
After each adjustment of the device properties, the KESO Integra Door Controller
must be programmed. Then check the LED indicator on the KESO Integra Door
Controller and test the functions using authorised data carriers.
Note
Relay 1 is permanently energised
(door is in the open state).
If the voltage drops, the continuously open command is
issued automatically. The voltage threshold for this condi-
tion is approximately 9 volts.
This field is only active if «External antenna» is selected.
The relay switching time can be set between 0.5 and
99.0 seconds.
With this function, the continuously open state
within a time window is no longer altered automati-
cally at the start. The continuously-open time window
is not activated or reset until a defined and authorised
Office Key or Office Master Key is held against the read-
er module. For authorisations, see Integra Authorisa-
tions in the k-entry
®
KESO management software.
Only active if the «Office/Shop function» is selected. If
this function is activated, the data carrier must be pre-
sented to the KESO Reader for approximately 2 seconds
in order to switch the «Office/Shop function» on or off.