Connection
Pos Description
POWER OUT 12 V – 24 V, maximum 1 A
1
Power supply for external devices, for exam-
ple a motorised lock.
Not available when using PoE (
2
USB connection, offline programming and firmware update
3
LOCK relay
Is switched via input access (
4
TIME relay – programmable
can be used as a switching timer
5
EXIT DEMAND input - configurable
Switches LOCK relay (
6
CONSTANTLY CLOSED input
Reader deactivated / permanently closed
7
LOCK / UNLOCKEDinput
Bolt switch contact
8
OPEN / CLOSED input
Door contact
9
RS-485 bus,
for Integra reader or Aperio™ hubs
10
KAPI connection
11
TCP IP - Optional Ethernet module
Switched off when power supply for external
1
devices (
) is used
12
DIP switches for configuration
13
No function assigned
14
RS-485 RELAY CARDS bus,
for relay boards
15
POWER IN
Power supply 12 – 24 V DC
1 0
).
5
)
3
)
LED
Pos Function
L1
Out of order
Ready for use
Errors
L3
COM – NO
COM – NC
L4
COM – NO
COM – NC
Circuit is open
L5
Circuit is closed
L6
Circuit is open
Circuit is closed
L7
Circuit is open
Circuit is closed
L8
Circuit is open
Circuit is closed
L9
Disabled
Enabled
L 1 0
Disabled
Enabled
L 1 1
Not connected
Connected
L 1 4
Bootloader active
the relay board is connected
L 1 5
Bootloader active and USB connected
Voltage applied
L3
–COM – NO
EN