Connection
Pos Description
POWER OUT 12 V – 24 V, maximum 1 A
1
Power supply for external devices, for exam-
ple a motorised lock.
Not available when using PoE (
2
USB connection, offline programming and firmware update
3
LOCK relay
Is switched via input access (
4
TIME relay – programmable
can be used as a switching timer
5
EXIT DEMAND input - configurable
Switches LOCK relay (
6
CONSTANTLY CLOSED input
Reader deactivated / permanently closed
7
LOCK / UNLOCKEDinput
Bolt switch contact
8
OPEN / CLOSED input
Door contact
9
RS-485 bus,
for Integra reader or Aperio™ hubs
10
KAPI connection
11
TCP IP - Optional Ethernet module
Switched off when power supply for external
1
devices (
) is used
12
DIP switches for configuration
13
No function assigned
14
RS-485 RELAY CARDS bus,
for relay boards
15
POWER IN
Power supply 12 – 24 V DC
1 0
).
5
)
3
)
LED
Pos Function
L1
Out of order
Ready for use
Errors
L3
COM – NO
COM – NC
L4
COM – NO
COM – NC
Circuit is open 
L5
Circuit is closed
L6
Circuit is open
Circuit is closed
L7
Circuit is open
Circuit is closed
L8
Circuit is open
Circuit is closed
L9
Disabled
Enabled
L 1 0
Disabled
Enabled
L 1 1
Not connected
Connected
L 1 4
Bootloader active
the relay board is connected
L 1 5
Bootloader active and USB connected
Voltage applied