Damaged electrical connection cable
The insulation on electrical connection cables is often damaged.
This may have the following causes:
• Pressure points, where connection cables are passed through
windows or doors
• Kinks where the connection cable has been improperly
fastened or routed
• Places where the connection cables have been cut due to
being driven over
• Insulation damage due to being ripped out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used
and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regularly.
Ensure that the connection cables are disconnected from
electrical power when checking for damage.
Electrical connection cables must comply with the applicable
VDE and DIN provisions.
Only use connection cables with the marking H 05 VV-F.
The printing of the type designation on the connection cable
is mandatory.
AC motor
The mains voltage must be 220-240 V~.
Extension cables up to 25 m long must have a cross-section of
1.5 square millimetres.
Connections and repair work on the electrical equipment may
only be carried out by electricians.
Please provide the following information in the event of any
enquiries:
• Type of current for the motor
• Data of machine type plate
12. Transport
• Transport the power tool by lifting it on the recesses provided
for this on the frame and the engine cover.
• Never use the protective devices for handling or transport.
• Make sure that the exposed part of the saw blade is covered
during transport, e.g. by the protective device.
13. Cleaning, maintenance and ordering
spare parts
WARNING
Always switch the machine off and remove the mains plug prior
to all maintenance and cleaning work.
13.1 Cleaning
Keep protective devices, air vents and the motor housing as
free of dust and dirt as possible. We recommend cleaning the
device directly after every use.
13.1.1 Exterior cleaning
• Clean the device at regular intervals using a damp cloth and
a little soft soap.
• Do not use cleaning agents or solvents. These could damage
the plastic parts of the device.
• Make sure that no water can penetrate the device interior.
10
GB/IE
13.1.2 Interior cleaning (fig. 15)
1. Open the storage box (9).
2. Remove the screw (35).
3. Loosen the screw (34).
4. Remove the cover (8).
5. Blow out the device interior with low-pressure compressed
air.
6. Attach the cover again (8).
7. Fasten the screw (34).
8. Insert the screw (35) again and tighten it.
9. Close the storage box (9).
13.2 Maintenance
13.2.1 Bearings (fig. 1/item 10)
Lubricate the bearing points (10) of the deflection rollers after
approx. 25-30 operating hours at the latest using high-quality
machine grease.
13.2.2 Carbon brushes
If excessive sparks are generated, have an electrician check
the carbon brushes.
ATTENTION
The carbon brushes must only be replaced by an electrician.
13.2.3 Mains cable
If the mains cable is pulled out, cut, or damaged in some other
form, then it should be replaced immediately.
13.2.4 Replacing the fine-wire fuse (fig. 16)
If the fine-wire fuse (36) is defective, it must be replaced with
a fine-wire fuse of the same type 5 A/250 V (ø 5 x 20 mm).
WARNING
Do not bypass the fine-wire fuse (36)! Do not use fuses of any
other type! This can lead to damage to the device.
13.3 Service information
With this product, it is necessary to note that the following
parts are subject to natural or usage-related wear, or that the
following parts are required as consumables.
Wearing parts*:Carbon brushes, saw blade, table inlay
* may not be included in the scope of supply!
13.4 Ordering spare parts
Please provide the following information when ordering
replacement parts (via the service-hotline):
• Device type
• Device article number (see packaging or instruction manual)
14. Storage
Store the device and its accessories in a dark, dry and frost-
free place that is inaccessible to children. The optimum storage
temperature lies between 5 and 30 ˚C. Store the power tool in
its original packaging.