11
11 Device Information
1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread
of heating water
3.3
Heat output / COP
3.4
Sound power level
3.5
Sound pressure level at a distance of 10 m
(air outlet side)
3.6
Heating water flow with an internal pressure
differential of
3.7
Air flow rate
3.8
Refrigerant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current A2 W35 / cos
5.4
5.5
max. power consumption of compressor protection
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
2. See CE declaration of conformity
3. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-8
All manuals and user guides at all-guides.com
°C / °C
°C
at A7 / W35
1
at A-7 / W35
kW / ---
1
at A-7 / W45
kW / ---
1
at A2 / W35
kW / ---
1
at A7 / W35
kW / ---
1
at A7 / W45
kW / ---
1
at A10 / W35
kW / ---
dB(A)
dB(A)
m³/h / Pa
m³/h
type / kg
H x W x L cm
Inch
kg
V / A
1
A2 W35
kW
A
A / ---
W
3
LA 11PS
IP 24
Outdoors
Up to 65 / above 18
-25 to +35
9.2
7.3 / 2.5
7.0 / 2.5
6.4 / 2.2
9.2 / 3.1
8.7 / 3.0
11.5 / 3.8
11.2 / 3.5
10.5 / 3.0
13.1 / 4.1
11.8 / 3.9
64
34
1.1 / 2600
2.1 / 9500
4000
R290 / 1.5
157 x 155 x 85
G 1" external
258
400 / 16
2.98
30
5.38
35
2
Automatic
Hot gas
Yes (heated)
Yes
2
External
5.0
2.9
5.23