7.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described in this document;
• Failure to observe installation rules;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, the assembly of devices of other manufacturers, making changes to the device
and natural wear.
8.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address
• Mod.:
= device name/model followed
• TS
= Temperature range within which product operation is guaranteed
• EPT15 .....
= ............
•
= In compliance with ATEX followed by Notified Body No.
• IP....
= Protection rating
• 230V....
= Power supply voltage, frequency (if Vac), followed by electrical absorption
Example of electrical absorption indication: 28/7 VA indicates 28 VA at start, 7 VA at steady state
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1904
= Lot issued in year 2019 in the 4th week
• 2093
= progressive job order number for the indicated year
• 00002
= progressive number referring to the quantity of the lot
CPS19... - CPS25...
Mod: CPS19-E T5008
EPT 15 ATEX 2188 X - IECEx EUT 15.0006 X
0477
IP66 - 230V50-60Hz 28/7 VA - 100% ED
Year: 2019
Threaded entry Type: 1/2 NPT
WARNING: Do not open when energized and in
10
Madas Technical Manual - 1|1.6c - REV. 0 of 3
TS: -40+60°C
II 2G Ex db IIC T5 Gb
Lot: U1904
2093/00002
presence of explosive atmosphere.
Flameproof joints cannot be respired.
Feb 2022
rd