Getting started
ELECTRIC SHOCK:
Before filling the pump, or before any maintenance operation, unplug the
pump from the mains
-
Install the pump in a place protected from rain and floodings, with
sufficient air flow
-
Pump has to be installed between the skimmer and the filter of the
swimming pool. The filter cap must be reachable easily, in order to ease
filter cleaning
-
Fix the pump in horizontal position, close from water, in order minimize
suction distance, and to reduce head losses
-
It is recommended not to install the pump more than 1 meter above he
water level, in order to ease priming process and pump functioning
-
Fill pump housinf with water (use opening 4a or
5a), untill the pump is full
-
Screw suction connector (4) and delivery
connector (5)
-
Connect the pump to the hoses of the swimming
pool system:
o If you have threaded connectors on your system that are compatible
with the pump, use PTFE to ensure airtightness of the connection
o If not, make the connection by sticking the hoses of your system with
pump connectors.
-
Open the gates of the system and plug the pump to the mains
-
Pump priming may take a few minutes.
Hoses of the system must be fixed in order to avoid mechanical constraints
on the pump
Suction hoses must be installed with regular slope, in order to avoid u-bend
and air pockets.